A novel stopped flow injection - Amperometric procedure for the determination of chlorate

A novel stopped flow injection - amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200 mV...

Full description

Saved in:
Bibliographic Details
Main Authors: Tue-Ngeun O., Jakmunee J., Grudpan K.
Format: Conference or Workshop Item
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-27744503906&partnerID=40&md5=0ce11a2c930cd906a5dded018d086755
http://cmuir.cmu.ac.th/handle/6653943832/4877
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-4877
record_format dspace
spelling th-cmuir.6653943832-48772014-08-30T02:55:54Z A novel stopped flow injection - Amperometric procedure for the determination of chlorate Tue-Ngeun O. Jakmunee J. Grudpan K. A novel stopped flow injection - amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200 mV versus Ag/AgCl electrode is employed. In order to increase sensitivity without using of too high acid concentration, promoting of the reaction by increasing reaction time and temperature can be carried out. This can be done without increase of dispersion of the product zone by stopping the flow while the injected zone is being in a mixing coil which is immersed in a water bath of 55 ± 0.5 °C. In a closed system of FIA, a side reaction of oxygen with iodide is also minimized. Under a set of conditions, linear calibration graphs were in the ranges of 1.2 × 10-6-6.0 × 10-5 mol l-1and 6.0 × 10-5-6.0 × 10-4 mol l-1. A sample throughput of 25 h-1 was accomplished. Relative standard deviation was 2% (n = 21, 1.2 × 10-4 mol l-1 chlorate). The proposed sFI-Amp procedure was successfully applied to the determination of chlorate in soil samples from longan plantation area. © 2005 Elsevier B.V. All rights reserved. 2014-08-30T02:55:54Z 2014-08-30T02:55:54Z 2005 Conference Paper 00399140 10.1016/j.talanta.2005.09.023 TLNTA http://www.scopus.com/inward/record.url?eid=2-s2.0-27744503906&partnerID=40&md5=0ce11a2c930cd906a5dded018d086755 http://cmuir.cmu.ac.th/handle/6653943832/4877 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description A novel stopped flow injection - amperometric (sFI-Amp) procedure for determination of chlorate has been developed. The reaction of chlorate with excess potassium iodide and hydrochloric acid, forming iodine/triiodide that is further electrochemically reduced at a glassy carbon electrode at +200 mV versus Ag/AgCl electrode is employed. In order to increase sensitivity without using of too high acid concentration, promoting of the reaction by increasing reaction time and temperature can be carried out. This can be done without increase of dispersion of the product zone by stopping the flow while the injected zone is being in a mixing coil which is immersed in a water bath of 55 ± 0.5 °C. In a closed system of FIA, a side reaction of oxygen with iodide is also minimized. Under a set of conditions, linear calibration graphs were in the ranges of 1.2 × 10-6-6.0 × 10-5 mol l-1and 6.0 × 10-5-6.0 × 10-4 mol l-1. A sample throughput of 25 h-1 was accomplished. Relative standard deviation was 2% (n = 21, 1.2 × 10-4 mol l-1 chlorate). The proposed sFI-Amp procedure was successfully applied to the determination of chlorate in soil samples from longan plantation area. © 2005 Elsevier B.V. All rights reserved.
format Conference or Workshop Item
author Tue-Ngeun O.
Jakmunee J.
Grudpan K.
spellingShingle Tue-Ngeun O.
Jakmunee J.
Grudpan K.
A novel stopped flow injection - Amperometric procedure for the determination of chlorate
author_facet Tue-Ngeun O.
Jakmunee J.
Grudpan K.
author_sort Tue-Ngeun O.
title A novel stopped flow injection - Amperometric procedure for the determination of chlorate
title_short A novel stopped flow injection - Amperometric procedure for the determination of chlorate
title_full A novel stopped flow injection - Amperometric procedure for the determination of chlorate
title_fullStr A novel stopped flow injection - Amperometric procedure for the determination of chlorate
title_full_unstemmed A novel stopped flow injection - Amperometric procedure for the determination of chlorate
title_sort novel stopped flow injection - amperometric procedure for the determination of chlorate
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-27744503906&partnerID=40&md5=0ce11a2c930cd906a5dded018d086755
http://cmuir.cmu.ac.th/handle/6653943832/4877
_version_ 1681420319757172736