Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system

A new extraction procedure based on an off-line extraction column was proposed for extracting of available phosphorus from soils. The column was fabricated from a plastic syringe fitted at the bottom with a cotton wool and a piece of filter paper to support a soil sample. An aliquot (50 mL) of extra...

Full description

Saved in:
Bibliographic Details
Main Authors: Jaroon Jakmunee, Jaroon Junsomboon
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650138555&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/48964
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-48964
record_format dspace
spelling th-cmuir.6653943832-489642018-08-16T02:07:19Z Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system Jaroon Jakmunee Jaroon Junsomboon Chemistry A new extraction procedure based on an off-line extraction column was proposed for extracting of available phosphorus from soils. The column was fabricated from a plastic syringe fitted at the bottom with a cotton wool and a piece of filter paper to support a soil sample. An aliquot (50 mL) of extracting solution (0.05 M HCl + 0.0125 M H2SO4) was used to extract the sample under gravity flow and the eluate was collected in a polyethylene bottle. The extract was then analyzed for phosphorus contents by a simple flow injection amperometric system, employing a set of three-way solenoid valves as an injection valve. The method is based on the electrochemical reduction of 12-molybdophosphate which is produced on-line by the reaction of orthophosphate with acidic molybdate and the electrical current produced was directly proportional to the concentration of phosphate in range of 0.1-10.0 mg L-1PO4-P, with a detection limit of 0.02 mg L-1. Relative standard for 11 replicate injections of 5 mg L-1PO4-P was 0.5%. A sample through put of 35 h-1was achieved, with consumption of 14 mg KCl, 10 mg ammonium molybdate and 0.05 mL H2SO4per analysis. The detection system does not suffer from the interferences that are encountered in the photometric method such as colored substances, colloids, metal ions, silicate and refractive index effect (Schlieren effect). The results obtained by the column extraction procedure were well correlated with those obtained by the steady-state extraction procedure, but showed slightly higher extraction efficiency. © 2009 Elsevier B.V. All rights reserved. 2018-08-16T02:07:19Z 2018-08-16T02:07:19Z 2009-09-15 Journal 00399140 2-s2.0-67650138555 10.1016/j.talanta.2009.01.028 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650138555&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/48964
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
spellingShingle Chemistry
Jaroon Jakmunee
Jaroon Junsomboon
Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
description A new extraction procedure based on an off-line extraction column was proposed for extracting of available phosphorus from soils. The column was fabricated from a plastic syringe fitted at the bottom with a cotton wool and a piece of filter paper to support a soil sample. An aliquot (50 mL) of extracting solution (0.05 M HCl + 0.0125 M H2SO4) was used to extract the sample under gravity flow and the eluate was collected in a polyethylene bottle. The extract was then analyzed for phosphorus contents by a simple flow injection amperometric system, employing a set of three-way solenoid valves as an injection valve. The method is based on the electrochemical reduction of 12-molybdophosphate which is produced on-line by the reaction of orthophosphate with acidic molybdate and the electrical current produced was directly proportional to the concentration of phosphate in range of 0.1-10.0 mg L-1PO4-P, with a detection limit of 0.02 mg L-1. Relative standard for 11 replicate injections of 5 mg L-1PO4-P was 0.5%. A sample through put of 35 h-1was achieved, with consumption of 14 mg KCl, 10 mg ammonium molybdate and 0.05 mL H2SO4per analysis. The detection system does not suffer from the interferences that are encountered in the photometric method such as colored substances, colloids, metal ions, silicate and refractive index effect (Schlieren effect). The results obtained by the column extraction procedure were well correlated with those obtained by the steady-state extraction procedure, but showed slightly higher extraction efficiency. © 2009 Elsevier B.V. All rights reserved.
format Journal
author Jaroon Jakmunee
Jaroon Junsomboon
author_facet Jaroon Jakmunee
Jaroon Junsomboon
author_sort Jaroon Jakmunee
title Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
title_short Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
title_full Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
title_fullStr Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
title_full_unstemmed Determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
title_sort determination of available phosphorus in soils by using a new extraction procedure and a flow injection amperometric system
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=67650138555&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/48964
_version_ 1681423324842819584