Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan
This paper investigates the 115kV transmission system development plan of Electricite du Laos (EDL), specifically for the transmission line projects in the Central-1 and Northern regions of the Lao PDR for the years 2010-2020. The steady-state power flow analysis at peak demand conditions is based o...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=69049102413&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49051 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-49051 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-490512018-08-16T02:09:00Z Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan P. Kongmany S. Premrudeepreechacharn K. Charoenpatcharakij Energy This paper investigates the 115kV transmission system development plan of Electricite du Laos (EDL), specifically for the transmission line projects in the Central-1 and Northern regions of the Lao PDR for the years 2010-2020. The steady-state power flow analysis at peak demand conditions is based on N-1 contingency criterion. The adjustment in transmission system development plan of EDL is to improve the reliability of such regional networks for the given years based on the economic justification (economic internal rate of return, EIRR and benefit cost ratio, B/C Ratio). The economic justification will be accomplished to indicate the internal rate of return and benefit cost ratio of each transmission system expansion project. This paper is used DIgSILENT program to calculate the steady-state power flow analysis and Transmission System Reliability Assessments. The results of the studies have shown that, power losses, energy not supplied (ENS), system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), are also reduced. In addition, the economic internal rate of return (EIRR) and benefit cost ratio, (B/C Ratio) of each project can assist planers to make a reasonable discussion or determination to reinforcement and expansion planning. © 2009 IEEE. 2018-08-16T02:09:00Z 2018-08-16T02:09:00Z 2009-08-27 Conference Proceeding 21574847 21574839 2-s2.0-69049102413 10.1109/APPEEC.2009.4918946 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=69049102413&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49051 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Energy |
spellingShingle |
Energy P. Kongmany S. Premrudeepreechacharn K. Charoenpatcharakij Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan |
description |
This paper investigates the 115kV transmission system development plan of Electricite du Laos (EDL), specifically for the transmission line projects in the Central-1 and Northern regions of the Lao PDR for the years 2010-2020. The steady-state power flow analysis at peak demand conditions is based on N-1 contingency criterion. The adjustment in transmission system development plan of EDL is to improve the reliability of such regional networks for the given years based on the economic justification (economic internal rate of return, EIRR and benefit cost ratio, B/C Ratio). The economic justification will be accomplished to indicate the internal rate of return and benefit cost ratio of each transmission system expansion project. This paper is used DIgSILENT program to calculate the steady-state power flow analysis and Transmission System Reliability Assessments. The results of the studies have shown that, power losses, energy not supplied (ENS), system average interruption frequency index (SAIFI), system average interruption duration index (SAIDI), are also reduced. In addition, the economic internal rate of return (EIRR) and benefit cost ratio, (B/C Ratio) of each project can assist planers to make a reasonable discussion or determination to reinforcement and expansion planning. © 2009 IEEE. |
format |
Conference Proceeding |
author |
P. Kongmany S. Premrudeepreechacharn K. Charoenpatcharakij |
author_facet |
P. Kongmany S. Premrudeepreechacharn K. Charoenpatcharakij |
author_sort |
P. Kongmany |
title |
Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan |
title_short |
Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan |
title_full |
Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan |
title_fullStr |
Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan |
title_full_unstemmed |
Transmission system reliability evaluation in the Central-1 and Northern regions of the Lao PDR in corresponding to transmission system development plan |
title_sort |
transmission system reliability evaluation in the central-1 and northern regions of the lao pdr in corresponding to transmission system development plan |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=69049102413&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49051 |
_version_ |
1681423340490719232 |