Performance evaluation of an electrometer system for ion and aerosol charge measurements

An aerosol electrometer system for measuring ion and aerosol charge using electrostatic detection technique was developed and presented. It consists of a size-selective inlet, a particle charger, an ion trap, a Faraday cup, an electrometer, and a data acquisition and processing system. In this syste...

Full description

Saved in:
Bibliographic Details
Main Authors: Panich Intra, Nakorn Tippayawong
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79551685975&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49797
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-49797
record_format dspace
spelling th-cmuir.6653943832-497972018-09-04T04:19:06Z Performance evaluation of an electrometer system for ion and aerosol charge measurements Panich Intra Nakorn Tippayawong Chemical Engineering Chemistry An aerosol electrometer system for measuring ion and aerosol charge using electrostatic detection technique was developed and presented. It consists of a size-selective inlet, a particle charger, an ion trap, a Faraday cup, an electrometer, and a data acquisition and processing system. In this system, an aerosol sample first passes through the size-selective inlet to remove particles outside the measurement size range based on their aerodynamic diameter, and then passes through the unipolar corona charger that sets a charge on the particles and enters the ion trap to remove the free ions. After the ion trap, the charged particles then enter the Faraday cup electrometer for measuring ultra low current of about 1 pA induced by ion and aerosol charge collected on the filter in Faraday cup corresponding to the number concentration of ion and aerosol. Signal current is then recorded and processed by a data acquisition system. Finally, the detailed description of the operating principle of the system as well as the preliminary experimental testing results of ion and aerosol charge measurements were also introduced and discussed. © 2011 Korean Institute of Chemical Engineers, Seoul, Korea. 2018-09-04T04:18:13Z 2018-09-04T04:18:13Z 2011-02-01 Journal 02561115 2-s2.0-79551685975 10.1007/s11814-010-0378-1 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79551685975&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49797
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemical Engineering
Chemistry
spellingShingle Chemical Engineering
Chemistry
Panich Intra
Nakorn Tippayawong
Performance evaluation of an electrometer system for ion and aerosol charge measurements
description An aerosol electrometer system for measuring ion and aerosol charge using electrostatic detection technique was developed and presented. It consists of a size-selective inlet, a particle charger, an ion trap, a Faraday cup, an electrometer, and a data acquisition and processing system. In this system, an aerosol sample first passes through the size-selective inlet to remove particles outside the measurement size range based on their aerodynamic diameter, and then passes through the unipolar corona charger that sets a charge on the particles and enters the ion trap to remove the free ions. After the ion trap, the charged particles then enter the Faraday cup electrometer for measuring ultra low current of about 1 pA induced by ion and aerosol charge collected on the filter in Faraday cup corresponding to the number concentration of ion and aerosol. Signal current is then recorded and processed by a data acquisition system. Finally, the detailed description of the operating principle of the system as well as the preliminary experimental testing results of ion and aerosol charge measurements were also introduced and discussed. © 2011 Korean Institute of Chemical Engineers, Seoul, Korea.
format Journal
author Panich Intra
Nakorn Tippayawong
author_facet Panich Intra
Nakorn Tippayawong
author_sort Panich Intra
title Performance evaluation of an electrometer system for ion and aerosol charge measurements
title_short Performance evaluation of an electrometer system for ion and aerosol charge measurements
title_full Performance evaluation of an electrometer system for ion and aerosol charge measurements
title_fullStr Performance evaluation of an electrometer system for ion and aerosol charge measurements
title_full_unstemmed Performance evaluation of an electrometer system for ion and aerosol charge measurements
title_sort performance evaluation of an electrometer system for ion and aerosol charge measurements
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79551685975&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49797
_version_ 1681423474715787264