Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples

A novel simultaneous injection effective mixing analysis system (SIEMA) for determination of direct bilirubin in urine sample was developed. Bilirubin reacts with diazotized sulfanilic acid in the presence of n-octyl-β-d- thioglucoside (OTG) as a solubilizing agent to form OTG-azobilirubin. The flow...

全面介紹

Saved in:
書目詳細資料
Main Authors: Kraingkrai Ponhong, Norio Teshima, Kate Grudpan, Shoji Motomizu, Tadao Sakai
格式: 雜誌
出版: 2018
主題:
在線閱讀:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=81355127204&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49804
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
機構: Chiang Mai University
id th-cmuir.6653943832-49804
record_format dspace
spelling th-cmuir.6653943832-498042018-09-04T04:18:19Z Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples Kraingkrai Ponhong Norio Teshima Kate Grudpan Shoji Motomizu Tadao Sakai Chemistry A novel simultaneous injection effective mixing analysis system (SIEMA) for determination of direct bilirubin in urine sample was developed. Bilirubin reacts with diazotized sulfanilic acid in the presence of n-octyl-β-d- thioglucoside (OTG) as a solubilizing agent to form OTG-azobilirubin. The flow and chemical variables were investigated. A linear calibration graph for direct bilirubin was obtained over the range of 0-1.0 mg L-1(r2= 0.994) with the limit of detection (3σ) of 4.7 μg L-1, and the relative standard deviation (RSD) being 1.9% (n = 11, 0.5 mg L-1of direct bilirubin). The results in healthy adult urine obtained by the proposed approach were found in good agreement with those obtained by the batch-wise diazo method. © 2011 Elsevier B.V. All rights reserved. 2018-09-04T04:18:19Z 2018-09-04T04:18:19Z 2011-12-15 Journal 00399140 2-s2.0-81355127204 10.1016/j.talanta.2011.09.048 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=81355127204&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49804
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
spellingShingle Chemistry
Kraingkrai Ponhong
Norio Teshima
Kate Grudpan
Shoji Motomizu
Tadao Sakai
Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
description A novel simultaneous injection effective mixing analysis system (SIEMA) for determination of direct bilirubin in urine sample was developed. Bilirubin reacts with diazotized sulfanilic acid in the presence of n-octyl-β-d- thioglucoside (OTG) as a solubilizing agent to form OTG-azobilirubin. The flow and chemical variables were investigated. A linear calibration graph for direct bilirubin was obtained over the range of 0-1.0 mg L-1(r2= 0.994) with the limit of detection (3σ) of 4.7 μg L-1, and the relative standard deviation (RSD) being 1.9% (n = 11, 0.5 mg L-1of direct bilirubin). The results in healthy adult urine obtained by the proposed approach were found in good agreement with those obtained by the batch-wise diazo method. © 2011 Elsevier B.V. All rights reserved.
format Journal
author Kraingkrai Ponhong
Norio Teshima
Kate Grudpan
Shoji Motomizu
Tadao Sakai
author_facet Kraingkrai Ponhong
Norio Teshima
Kate Grudpan
Shoji Motomizu
Tadao Sakai
author_sort Kraingkrai Ponhong
title Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
title_short Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
title_full Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
title_fullStr Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
title_full_unstemmed Simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
title_sort simultaneous injection effective mixing analysis system for the determination of direct bilirubin in urinary samples
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=81355127204&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49804
_version_ 1681423475973029888