Placement and removal torque values of orthodontic miniscrew implants

Introduction: The purpose of this study was to analyze the maximum insertion torque (MIT) and maximum removal torque (MRT) values of orthodontic miniscrews. Methods: Two hundred eighty titanium miniscrews were placed in several sites in the maxillae and mandibles of orthodontic patients to provide s...

Full description

Saved in:
Bibliographic Details
Main Authors: Eduardo Yugo Suzuki, Boonsiva Suzuki
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79955591942&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49899
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-49899
record_format dspace
spelling th-cmuir.6653943832-498992018-09-04T04:19:59Z Placement and removal torque values of orthodontic miniscrew implants Eduardo Yugo Suzuki Boonsiva Suzuki Dentistry Introduction: The purpose of this study was to analyze the maximum insertion torque (MIT) and maximum removal torque (MRT) values of orthodontic miniscrews. Methods: Two hundred eighty titanium miniscrews were placed in several sites in the maxillae and mandibles of orthodontic patients to provide skeletal anchorage. Two types of miniscrews were used: predrilling, cylindrical miniscrews, and self-drilling, conical miniscrews. A force of 50 g was applied with nickel-titanium coil springs 2 weeks after placement. MIT and MRT values were assessed with a digital torque gauge. Torque values were subjected to the paired t test, Student t test, chi-square test, and 1-way analysis of variance (ANOVA) (P <0.05). Results: MIT values were significantly higher for the self-drilling miniscrews (mean, 14.5 Ncm; 95% CI, 13.6-15.3) than for the predrilling miniscrews (mean, 9.2 Ncm; 95% CI, 8.6-9.9) in all implant sites. For both predrilling and self-drilling miniscrews, the highest MIT values were observed at the midpalatal suture site followed by the dentoalveolar bones of the mandible and maxilla, respectively. In contrast, MRT values were significantly higher for the predrilling miniscrews (mean, 22.6 Ncm; 95% CI, 22.0-23.3) than for the self-drilling miniscrews (mean, 17.6 Ncm; 95% CI, 16.8-18.4). Accordingly, the mean torque ratio of predrilling miniscrews was twice that of the self-drilling miniscrews. Conclusions: An inverse relationship between MIT and MRT values was observed. The results suggest that relatively lower MIT values were more favorable to osseointegration than higher values. Copyright © 2011 by the American Association of Orthodontists. 2018-09-04T04:19:59Z 2018-09-04T04:19:59Z 2011-05-01 Journal 08895406 2-s2.0-79955591942 10.1016/j.ajodo.2010.11.017 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79955591942&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49899
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Dentistry
spellingShingle Dentistry
Eduardo Yugo Suzuki
Boonsiva Suzuki
Placement and removal torque values of orthodontic miniscrew implants
description Introduction: The purpose of this study was to analyze the maximum insertion torque (MIT) and maximum removal torque (MRT) values of orthodontic miniscrews. Methods: Two hundred eighty titanium miniscrews were placed in several sites in the maxillae and mandibles of orthodontic patients to provide skeletal anchorage. Two types of miniscrews were used: predrilling, cylindrical miniscrews, and self-drilling, conical miniscrews. A force of 50 g was applied with nickel-titanium coil springs 2 weeks after placement. MIT and MRT values were assessed with a digital torque gauge. Torque values were subjected to the paired t test, Student t test, chi-square test, and 1-way analysis of variance (ANOVA) (P <0.05). Results: MIT values were significantly higher for the self-drilling miniscrews (mean, 14.5 Ncm; 95% CI, 13.6-15.3) than for the predrilling miniscrews (mean, 9.2 Ncm; 95% CI, 8.6-9.9) in all implant sites. For both predrilling and self-drilling miniscrews, the highest MIT values were observed at the midpalatal suture site followed by the dentoalveolar bones of the mandible and maxilla, respectively. In contrast, MRT values were significantly higher for the predrilling miniscrews (mean, 22.6 Ncm; 95% CI, 22.0-23.3) than for the self-drilling miniscrews (mean, 17.6 Ncm; 95% CI, 16.8-18.4). Accordingly, the mean torque ratio of predrilling miniscrews was twice that of the self-drilling miniscrews. Conclusions: An inverse relationship between MIT and MRT values was observed. The results suggest that relatively lower MIT values were more favorable to osseointegration than higher values. Copyright © 2011 by the American Association of Orthodontists.
format Journal
author Eduardo Yugo Suzuki
Boonsiva Suzuki
author_facet Eduardo Yugo Suzuki
Boonsiva Suzuki
author_sort Eduardo Yugo Suzuki
title Placement and removal torque values of orthodontic miniscrew implants
title_short Placement and removal torque values of orthodontic miniscrew implants
title_full Placement and removal torque values of orthodontic miniscrew implants
title_fullStr Placement and removal torque values of orthodontic miniscrew implants
title_full_unstemmed Placement and removal torque values of orthodontic miniscrew implants
title_sort placement and removal torque values of orthodontic miniscrew implants
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79955591942&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49899
_version_ 1681423493028118528