Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters
Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate a...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-17744362273&partnerID=40&md5=bf39c62fa28ddcc15be5ec1c04a1a6b3 http://www.ncbi.nlm.nih.gov/pubmed/18970007 http://cmuir.cmu.ac.th/handle/6653943832/4992 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-4992 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-49922014-08-30T02:56:02Z Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters Udnan Y. McKelvie I.D. Grace M.R. Jakmunee J. Grudpan K. Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1 and sample throughput of 70 samples h-1 were achieved. The relative standard deviations for 50 and 500 μg P l-1 orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l -1 was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1 standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved. 2014-08-30T02:56:02Z 2014-08-30T02:56:02Z 2005 Article 00399140 10.1016/j.talanta.2004.12.064 18970007 TLNTA http://www.scopus.com/inward/record.url?eid=2-s2.0-17744362273&partnerID=40&md5=bf39c62fa28ddcc15be5ec1c04a1a6b3 http://www.ncbi.nlm.nih.gov/pubmed/18970007 http://cmuir.cmu.ac.th/handle/6653943832/4992 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l-1 and sample throughput of 70 samples h-1 were achieved. The relative standard deviations for 50 and 500 μg P l-1 orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l -1 was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l-1 standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples. © 2005 Elsevier B.V. All rights reserved. |
format |
Article |
author |
Udnan Y. McKelvie I.D. Grace M.R. Jakmunee J. Grudpan K. |
spellingShingle |
Udnan Y. McKelvie I.D. Grace M.R. Jakmunee J. Grudpan K. Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
author_facet |
Udnan Y. McKelvie I.D. Grace M.R. Jakmunee J. Grudpan K. |
author_sort |
Udnan Y. |
title |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_short |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_full |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_fullStr |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_full_unstemmed |
Evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
title_sort |
evaluation of on-line preconcentration and flow-injection amperometry for phosphate determination in fresh and marine waters |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-17744362273&partnerID=40&md5=bf39c62fa28ddcc15be5ec1c04a1a6b3 http://www.ncbi.nlm.nih.gov/pubmed/18970007 http://cmuir.cmu.ac.th/handle/6653943832/4992 |
_version_ |
1681420341211037696 |