Experimental investigations on spray characteristics in twin-fluid atomizer

A twin-fluid atomizer was designed and developed for fuel atomization. The droplet characteristic in the spray which was produced with the atomizer was investigated experimentally. Air flow induced in the atomizer causes a pressure reduction, hence the fuel is sucked into the atomizer. The mixture f...

Full description

Saved in:
Bibliographic Details
Main Authors: Pipatpong Watanawanyoo, Hiroyuki Hirahara, Hirofumi Mochida, Teruyuki Furukawa, Masanori Nakamura, Sumpun Chaitep
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84855735451&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49930
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-49930
record_format dspace
spelling th-cmuir.6653943832-499302018-09-04T04:20:29Z Experimental investigations on spray characteristics in twin-fluid atomizer Pipatpong Watanawanyoo Hiroyuki Hirahara Hirofumi Mochida Teruyuki Furukawa Masanori Nakamura Sumpun Chaitep Engineering A twin-fluid atomizer was designed and developed for fuel atomization. The droplet characteristic in the spray which was produced with the atomizer was investigated experimentally. Air flow induced in the atomizer causes a pressure reduction, hence the fuel is sucked into the atomizer. The mixture flow of air and liquid caused the atomization downstream due to the turbulence. In the twin-fluid atomizer, atomization is attained by injecting an air stream at tip of the liquid inlet port. In this research, the test liquid supply pressure was kept constant and the air flow rate through the atomizer was varied over a range of air supply pressure to obtain the variation in air liquid mass flow ratio (ALR) from 0.2 to 2.7. The results revealed that the air assisted atomizer had a capability to inject the test liquid in the range of the rates of 0.0019-0.00426 kg/s, with the use of air pressure supplied from 68.9 to 689 kPa. The images of the spray were obtained with a shadowgraph technique and analyzed to obtain the particle size and its distribution. Droplet size from twin-fluid atomizer had various sizes in the range of about 17-200 μm. The atomizer can be applied for aerosol and combustion purposes. © 2011 Published by Elsevier Ltd. 2018-09-04T04:20:29Z 2018-09-04T04:20:29Z 2011-12-01 Conference Proceeding 18777058 2-s2.0-84855735451 10.1016/j.proeng.2011.12.416 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84855735451&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/49930
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Engineering
spellingShingle Engineering
Pipatpong Watanawanyoo
Hiroyuki Hirahara
Hirofumi Mochida
Teruyuki Furukawa
Masanori Nakamura
Sumpun Chaitep
Experimental investigations on spray characteristics in twin-fluid atomizer
description A twin-fluid atomizer was designed and developed for fuel atomization. The droplet characteristic in the spray which was produced with the atomizer was investigated experimentally. Air flow induced in the atomizer causes a pressure reduction, hence the fuel is sucked into the atomizer. The mixture flow of air and liquid caused the atomization downstream due to the turbulence. In the twin-fluid atomizer, atomization is attained by injecting an air stream at tip of the liquid inlet port. In this research, the test liquid supply pressure was kept constant and the air flow rate through the atomizer was varied over a range of air supply pressure to obtain the variation in air liquid mass flow ratio (ALR) from 0.2 to 2.7. The results revealed that the air assisted atomizer had a capability to inject the test liquid in the range of the rates of 0.0019-0.00426 kg/s, with the use of air pressure supplied from 68.9 to 689 kPa. The images of the spray were obtained with a shadowgraph technique and analyzed to obtain the particle size and its distribution. Droplet size from twin-fluid atomizer had various sizes in the range of about 17-200 μm. The atomizer can be applied for aerosol and combustion purposes. © 2011 Published by Elsevier Ltd.
format Conference Proceeding
author Pipatpong Watanawanyoo
Hiroyuki Hirahara
Hirofumi Mochida
Teruyuki Furukawa
Masanori Nakamura
Sumpun Chaitep
author_facet Pipatpong Watanawanyoo
Hiroyuki Hirahara
Hirofumi Mochida
Teruyuki Furukawa
Masanori Nakamura
Sumpun Chaitep
author_sort Pipatpong Watanawanyoo
title Experimental investigations on spray characteristics in twin-fluid atomizer
title_short Experimental investigations on spray characteristics in twin-fluid atomizer
title_full Experimental investigations on spray characteristics in twin-fluid atomizer
title_fullStr Experimental investigations on spray characteristics in twin-fluid atomizer
title_full_unstemmed Experimental investigations on spray characteristics in twin-fluid atomizer
title_sort experimental investigations on spray characteristics in twin-fluid atomizer
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84855735451&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/49930
_version_ 1681423498630660096