Loading of a single implant in simulated bone
This study investigated the effect of occlusal design on the strain developed in simulated bone of implant-supported single crown models. Triaxial strain gauges were attached at the cervical area of each model. Occlusal design, load location, and magnitude were examined to determine the maximum axia...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79957888210&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50301 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-50301 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-503012018-09-04T04:28:07Z Loading of a single implant in simulated bone Pimduen Rungsiyakull Chaiy Rungsiyakull Richard Appleyard Qing Li Micheal Swain Iven Klineberg Medicine This study investigated the effect of occlusal design on the strain developed in simulated bone of implant-supported single crown models. Triaxial strain gauges were attached at the cervical area of each model. Occlusal design, load location, and magnitude were examined to determine the maximum axial principal strains (µε) of four occlusal designs: 30-degree cusp inclination with 4- and 6-mm occlusal table dimensions and a 10-degree cusp inclination with 4- and 6-mm occlusal table dimensions. Statistical differences were found for peak average maximum principal strains between each occlusal design when the applied load was directed along the central fossa and 2 mm buccal to the central fossa along the inclined plane, with strain gauges attached at the cervicobuccal (P < .001) and cervicolingual (P ≤ .001) aspects. In all loading conditions, the 30-degree cusp inclination and 6-mm occlusal table dimension consistently presented the largest strains compared with the other occlusal designs. A reduced cusp inclination and occlusal table dimension effectively reduced experimental bone strain on implantsupported single crowns. The occlusal table dimension appeared to have a relatively more important role than cusp inclination. © 2011 by Quintessence Publishing Co Inc. 2018-09-04T04:28:07Z 2018-09-04T04:28:07Z 2011-01-01 Journal 08932174 2-s2.0-79957888210 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79957888210&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50301 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Medicine |
spellingShingle |
Medicine Pimduen Rungsiyakull Chaiy Rungsiyakull Richard Appleyard Qing Li Micheal Swain Iven Klineberg Loading of a single implant in simulated bone |
description |
This study investigated the effect of occlusal design on the strain developed in simulated bone of implant-supported single crown models. Triaxial strain gauges were attached at the cervical area of each model. Occlusal design, load location, and magnitude were examined to determine the maximum axial principal strains (µε) of four occlusal designs: 30-degree cusp inclination with 4- and 6-mm occlusal table dimensions and a 10-degree cusp inclination with 4- and 6-mm occlusal table dimensions. Statistical differences were found for peak average maximum principal strains between each occlusal design when the applied load was directed along the central fossa and 2 mm buccal to the central fossa along the inclined plane, with strain gauges attached at the cervicobuccal (P < .001) and cervicolingual (P ≤ .001) aspects. In all loading conditions, the 30-degree cusp inclination and 6-mm occlusal table dimension consistently presented the largest strains compared with the other occlusal designs. A reduced cusp inclination and occlusal table dimension effectively reduced experimental bone strain on implantsupported single crowns. The occlusal table dimension appeared to have a relatively more important role than cusp inclination. © 2011 by Quintessence Publishing Co Inc. |
format |
Journal |
author |
Pimduen Rungsiyakull Chaiy Rungsiyakull Richard Appleyard Qing Li Micheal Swain Iven Klineberg |
author_facet |
Pimduen Rungsiyakull Chaiy Rungsiyakull Richard Appleyard Qing Li Micheal Swain Iven Klineberg |
author_sort |
Pimduen Rungsiyakull |
title |
Loading of a single implant in simulated bone |
title_short |
Loading of a single implant in simulated bone |
title_full |
Loading of a single implant in simulated bone |
title_fullStr |
Loading of a single implant in simulated bone |
title_full_unstemmed |
Loading of a single implant in simulated bone |
title_sort |
loading of a single implant in simulated bone |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79957888210&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50301 |
_version_ |
1681423565110378496 |