Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
We report a novel system to analyze atmospheric nitrophenols (NPs). Rain or air sample extracts (1 mL) are preconcentrated on a narrow bore (2 mm) aliphatic anion exchanger. In the absence of strong retention of NPs exhibited by aromatic ion exchangers, retained NPs are eluted as a plug by injection...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954194438&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50666 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-50666 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-506662018-09-04T04:43:45Z Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry Lucksagoon Ganranoo Santosh K. Mishra Abul K. Azad Ado Shigihara Purnendu K. Dasgupta Zachary S. Breitbach Daniel W. Armstrong Kate Grudpan Bernhard Rappenglueck Chemistry We report a novel system to analyze atmospheric nitrophenols (NPs). Rain or air sample extracts (1 mL) are preconcentrated on a narrow bore (2 mm) aliphatic anion exchanger. In the absence of strong retention of NPs exhibited by aromatic ion exchangers, retained NPs are eluted as a plug by injection of 100 μL of 0.1 M Na2SO4 on to a short (2×50 mm) reverse phase C-18 column packed with 2.2 μm particles. The salt plug passes through the C-18 column unretained while the NPs are separated by an ammonium acetate buffered methanol-water eluent, compatible with mass spectrometry (MS). The eluted NPs are measured with a long path Teflon AF-based liquid core waveguide (0.15×1420 mm) illuminated by a 403 nm light emitting diode and detected by a monolithic photodiode-operational amplifier. The waveguide is rendered chemically active by suspending it over concentrated ammonia that permeates into the lumen. The NPs ionize to the yellow anion form (λmax ∼400 nm). The separation of 4-nitrophenol, 2,4-dinitrophenol, 2-methyl-4-nitrophenol, 3-methyl-4-nitrophenol, and 2-nitrophenol (these are the dominant NPs, typically in that order, in both rain and air of Houston and Arlington, TX, confirmed by tandem MS) takes just over 5 min with respective S/N = 3 limits of detection (LODs) of 60, 12, 30, 67, and 23 pg/mL compared to MS/MS LODs of 20, 49, 11, 20, and 210 pg/mL. Illustrative air and rain data are presented. © 2010 American Chemical Society. 2018-09-04T04:43:45Z 2018-09-04T04:43:45Z 2010-07-01 Journal 00032700 2-s2.0-77954194438 10.1021/ac101015y https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954194438&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50666 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Chemistry |
spellingShingle |
Chemistry Lucksagoon Ganranoo Santosh K. Mishra Abul K. Azad Ado Shigihara Purnendu K. Dasgupta Zachary S. Breitbach Daniel W. Armstrong Kate Grudpan Bernhard Rappenglueck Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
description |
We report a novel system to analyze atmospheric nitrophenols (NPs). Rain or air sample extracts (1 mL) are preconcentrated on a narrow bore (2 mm) aliphatic anion exchanger. In the absence of strong retention of NPs exhibited by aromatic ion exchangers, retained NPs are eluted as a plug by injection of 100 μL of 0.1 M Na2SO4 on to a short (2×50 mm) reverse phase C-18 column packed with 2.2 μm particles. The salt plug passes through the C-18 column unretained while the NPs are separated by an ammonium acetate buffered methanol-water eluent, compatible with mass spectrometry (MS). The eluted NPs are measured with a long path Teflon AF-based liquid core waveguide (0.15×1420 mm) illuminated by a 403 nm light emitting diode and detected by a monolithic photodiode-operational amplifier. The waveguide is rendered chemically active by suspending it over concentrated ammonia that permeates into the lumen. The NPs ionize to the yellow anion form (λmax ∼400 nm). The separation of 4-nitrophenol, 2,4-dinitrophenol, 2-methyl-4-nitrophenol, 3-methyl-4-nitrophenol, and 2-nitrophenol (these are the dominant NPs, typically in that order, in both rain and air of Houston and Arlington, TX, confirmed by tandem MS) takes just over 5 min with respective S/N = 3 limits of detection (LODs) of 60, 12, 30, 67, and 23 pg/mL compared to MS/MS LODs of 20, 49, 11, 20, and 210 pg/mL. Illustrative air and rain data are presented. © 2010 American Chemical Society. |
format |
Journal |
author |
Lucksagoon Ganranoo Santosh K. Mishra Abul K. Azad Ado Shigihara Purnendu K. Dasgupta Zachary S. Breitbach Daniel W. Armstrong Kate Grudpan Bernhard Rappenglueck |
author_facet |
Lucksagoon Ganranoo Santosh K. Mishra Abul K. Azad Ado Shigihara Purnendu K. Dasgupta Zachary S. Breitbach Daniel W. Armstrong Kate Grudpan Bernhard Rappenglueck |
author_sort |
Lucksagoon Ganranoo |
title |
Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
title_short |
Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
title_full |
Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
title_fullStr |
Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
title_full_unstemmed |
Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
title_sort |
measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954194438&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50666 |
_version_ |
1681423630914813952 |