Lightning performance of covered conductors overhead distribution lines
This paper analyzes the lightning performance of 22 kV, ChiangMai substation 4 to Doi-Suthep, overhead distribution line with covered conductors. The performance of line which related to the insulator flashover has been modeled and analyzed using EMTP. The backflashover rate (BFOR), shielding failur...
Saved in:
Main Author: | |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954925654&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50719 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-50719 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-507192018-09-04T04:45:55Z Lightning performance of covered conductors overhead distribution lines T. Thanasaksiri Computer Science Engineering This paper analyzes the lightning performance of 22 kV, ChiangMai substation 4 to Doi-Suthep, overhead distribution line with covered conductors. The performance of line which related to the insulator flashover has been modeled and analyzed using EMTP. The backflashover rate (BFOR), shielding failure flashover rate (SFFOR) and induced voltage flashover rate (IVFOR) of line have been determined. The number of lightning flashovers from simulation, by applying ground flash density Ng=6.5x10-5Td 2.277, are close with the data from the line outages recorder. 2018-09-04T04:44:40Z 2018-09-04T04:44:40Z 2010-07-30 Conference Proceeding 2-s2.0-77954925654 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954925654&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50719 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Computer Science Engineering |
spellingShingle |
Computer Science Engineering T. Thanasaksiri Lightning performance of covered conductors overhead distribution lines |
description |
This paper analyzes the lightning performance of 22 kV, ChiangMai substation 4 to Doi-Suthep, overhead distribution line with covered conductors. The performance of line which related to the insulator flashover has been modeled and analyzed using EMTP. The backflashover rate (BFOR), shielding failure flashover rate (SFFOR) and induced voltage flashover rate (IVFOR) of line have been determined. The number of lightning flashovers from simulation, by applying ground flash density Ng=6.5x10-5Td 2.277, are close with the data from the line outages recorder. |
format |
Conference Proceeding |
author |
T. Thanasaksiri |
author_facet |
T. Thanasaksiri |
author_sort |
T. Thanasaksiri |
title |
Lightning performance of covered conductors overhead distribution lines |
title_short |
Lightning performance of covered conductors overhead distribution lines |
title_full |
Lightning performance of covered conductors overhead distribution lines |
title_fullStr |
Lightning performance of covered conductors overhead distribution lines |
title_full_unstemmed |
Lightning performance of covered conductors overhead distribution lines |
title_sort |
lightning performance of covered conductors overhead distribution lines |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954925654&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/50719 |
_version_ |
1681423640542838784 |