Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes

PurposeTo compare the accuracy and reliability of intraocular lens (IOL) master and A-scan immersion biometry in silicone oil (SO)-filled eyes.MethodsA prospective, consecutive, nonrandomized study was performed in 34 SO-filled eyes of 34 patients, who underwent a pars plana vitrectomy, with SO remo...

Full description

Saved in:
Bibliographic Details
Main Authors: P. Kunavisarut, P. Poopattanakul, C. Intarated, K. Pathanapitoon
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84867511211&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51326
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-51326
record_format dspace
spelling th-cmuir.6653943832-513262018-09-04T06:12:23Z Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes P. Kunavisarut P. Poopattanakul C. Intarated K. Pathanapitoon Arts and Humanities Medicine PurposeTo compare the accuracy and reliability of intraocular lens (IOL) master and A-scan immersion biometry in silicone oil (SO)-filled eyes.MethodsA prospective, consecutive, nonrandomized study was performed in 34 SO-filled eyes of 34 patients, who underwent a pars plana vitrectomy, with SO removal and cataract surgery, as well as IOL implantation. Both IOL master and immersion A-scan were performed to measure the axial length (AXL) before SO removal. Three months after removal of the SO, AXL measurements using IOL master and refraction was performed. Accuracy of the two techniques was determined by a mean postoperative AXL using an IOL master and reliability was determined by mean actual postoperative refractive error.ResultsPreoperative mean AXL was 23.91±0.24 mm (range 21.33-28.61 mm) and 23.71±0.59 mm (range 19.27-36.18 mm) by IOL master and A-scan immersion, respectively. Postoperative mean AXL by IOL master was 23.90±0.23 mm (range 21.58-27.94 mm), which showed a statistically significant difference from the preoperative mean AXL by A-scan immersion (P0.005). The AXL measurement by IOL master also was more accurate than A-scan immersion by Pearsons correlation (0.966 vs 0.410). For reliability of the two techniques, the predictive postoperative refractive error in A-scan immersion (mean 1.79±1.04 D, range 14.62 to 16.41 D) was greater than that in IOL master (mean 0.60±0.23 D, range 2.74 to 2.33 D), with a statistically significant difference (P0.049).ConclusionIOL master had more accuracy and less deviation in predictive postoperative refractive error than A-scan immersion in SO-filled eyes. © 2012 Macmillan Publishers Limited All rights reserved. 2018-09-04T06:00:17Z 2018-09-04T06:00:17Z 2012-01-01 Journal 14765454 0950222X 2-s2.0-84867511211 10.1038/eye.2012.163 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84867511211&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51326
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Arts and Humanities
Medicine
spellingShingle Arts and Humanities
Medicine
P. Kunavisarut
P. Poopattanakul
C. Intarated
K. Pathanapitoon
Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes
description PurposeTo compare the accuracy and reliability of intraocular lens (IOL) master and A-scan immersion biometry in silicone oil (SO)-filled eyes.MethodsA prospective, consecutive, nonrandomized study was performed in 34 SO-filled eyes of 34 patients, who underwent a pars plana vitrectomy, with SO removal and cataract surgery, as well as IOL implantation. Both IOL master and immersion A-scan were performed to measure the axial length (AXL) before SO removal. Three months after removal of the SO, AXL measurements using IOL master and refraction was performed. Accuracy of the two techniques was determined by a mean postoperative AXL using an IOL master and reliability was determined by mean actual postoperative refractive error.ResultsPreoperative mean AXL was 23.91±0.24 mm (range 21.33-28.61 mm) and 23.71±0.59 mm (range 19.27-36.18 mm) by IOL master and A-scan immersion, respectively. Postoperative mean AXL by IOL master was 23.90±0.23 mm (range 21.58-27.94 mm), which showed a statistically significant difference from the preoperative mean AXL by A-scan immersion (P0.005). The AXL measurement by IOL master also was more accurate than A-scan immersion by Pearsons correlation (0.966 vs 0.410). For reliability of the two techniques, the predictive postoperative refractive error in A-scan immersion (mean 1.79±1.04 D, range 14.62 to 16.41 D) was greater than that in IOL master (mean 0.60±0.23 D, range 2.74 to 2.33 D), with a statistically significant difference (P0.049).ConclusionIOL master had more accuracy and less deviation in predictive postoperative refractive error than A-scan immersion in SO-filled eyes. © 2012 Macmillan Publishers Limited All rights reserved.
format Journal
author P. Kunavisarut
P. Poopattanakul
C. Intarated
K. Pathanapitoon
author_facet P. Kunavisarut
P. Poopattanakul
C. Intarated
K. Pathanapitoon
author_sort P. Kunavisarut
title Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes
title_short Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes
title_full Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes
title_fullStr Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes
title_full_unstemmed Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes
title_sort accuracy and reliability of iol master and a-scan immersion biometry in silicone oil-filled eyes
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84867511211&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51326
_version_ 1681423749593694208