Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV

Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experienc...

Full description

Saved in:
Bibliographic Details
Main Authors: Wichet Thipprasert, Peerapol Jirapong
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866760688&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51514
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-51514
record_format dspace
spelling th-cmuir.6653943832-515142018-09-04T06:05:01Z Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV Wichet Thipprasert Peerapol Jirapong Computer Science Engineering Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm 2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm 2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE. 2018-09-04T06:03:37Z 2018-09-04T06:03:37Z 2012-10-02 Conference Proceeding 2-s2.0-84866760688 10.1109/ECTICon.2012.6254199 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866760688&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51514
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Computer Science
Engineering
spellingShingle Computer Science
Engineering
Wichet Thipprasert
Peerapol Jirapong
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
description Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm 2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm 2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE.
format Conference Proceeding
author Wichet Thipprasert
Peerapol Jirapong
author_facet Wichet Thipprasert
Peerapol Jirapong
author_sort Wichet Thipprasert
title Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
title_short Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
title_full Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
title_fullStr Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
title_full_unstemmed Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
title_sort comparison of ac flashover performance for line post and pin post insulators in distribution 22 kv
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866760688&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51514
_version_ 1681423783552876544