Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experienc...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866760688&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51514 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-51514 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-515142018-09-04T06:05:01Z Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV Wichet Thipprasert Peerapol Jirapong Computer Science Engineering Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm 2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm 2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE. 2018-09-04T06:03:37Z 2018-09-04T06:03:37Z 2012-10-02 Conference Proceeding 2-s2.0-84866760688 10.1109/ECTICon.2012.6254199 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866760688&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51514 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Computer Science Engineering |
spellingShingle |
Computer Science Engineering Wichet Thipprasert Peerapol Jirapong Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
description |
Electrical insulators of the Provincial Electricity Authority (PEA) of medium system are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm 2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm 2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE. |
format |
Conference Proceeding |
author |
Wichet Thipprasert Peerapol Jirapong |
author_facet |
Wichet Thipprasert Peerapol Jirapong |
author_sort |
Wichet Thipprasert |
title |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_short |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_full |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_fullStr |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_full_unstemmed |
Comparison of AC flashover performance for line post and pin post insulators in distribution 22 kV |
title_sort |
comparison of ac flashover performance for line post and pin post insulators in distribution 22 kv |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866760688&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51514 |
_version_ |
1681423783552876544 |