AC flashover performance of porcelain insulators in distribution systems

This paper presents an experiment on the different artificial pollution tests based on IEC 60507. The insulators, in the chamber for tests, used the standard medium system 22 kV. The insulators were tested with each type consisting of leakage current (LC) and flashover voltage (FOV) performance of t...

Full description

Saved in:
Bibliographic Details
Main Authors: Wichet Thippresert, Peerapol Jirapong
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84861950005&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51580
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-51580
record_format dspace
spelling th-cmuir.6653943832-515802018-09-04T06:04:36Z AC flashover performance of porcelain insulators in distribution systems Wichet Thippresert Peerapol Jirapong Energy This paper presents an experiment on the different artificial pollution tests based on IEC 60507. The insulators, in the chamber for tests, used the standard medium system 22 kV. The insulators were tested with each type consisting of leakage current (LC) and flashover voltage (FOV) performance of the coating of the insulator surface, with and without semiconductor. The salt fog test results showed that FOV performance of the pin post insulator with surface without coating is less than 38 percent of dry test FOV level at equivalent salt deposit density (ESDD) = 0.5 mg/cm2. The LC of Line post insulator of a surface without a coating is less than three types of porcelain insulators, in the medium system, with 10 mA at ESDD = 0.3 mg/cm2, at a nominal voltage. This data will be useful as a guideline in cases to take insulators surface coating by the semiconductor of distribution system, to reduce the maintenance cost. Moreover, it will be useful to select or design the suitable insulators for use in polluted areas. 2018-09-04T06:04:36Z 2018-09-04T06:04:36Z 2012-06-12 Conference Proceeding 2-s2.0-84861950005 10.2316/P.2012.768-045 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84861950005&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51580
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
Wichet Thippresert
Peerapol Jirapong
AC flashover performance of porcelain insulators in distribution systems
description This paper presents an experiment on the different artificial pollution tests based on IEC 60507. The insulators, in the chamber for tests, used the standard medium system 22 kV. The insulators were tested with each type consisting of leakage current (LC) and flashover voltage (FOV) performance of the coating of the insulator surface, with and without semiconductor. The salt fog test results showed that FOV performance of the pin post insulator with surface without coating is less than 38 percent of dry test FOV level at equivalent salt deposit density (ESDD) = 0.5 mg/cm2. The LC of Line post insulator of a surface without a coating is less than three types of porcelain insulators, in the medium system, with 10 mA at ESDD = 0.3 mg/cm2, at a nominal voltage. This data will be useful as a guideline in cases to take insulators surface coating by the semiconductor of distribution system, to reduce the maintenance cost. Moreover, it will be useful to select or design the suitable insulators for use in polluted areas.
format Conference Proceeding
author Wichet Thippresert
Peerapol Jirapong
author_facet Wichet Thippresert
Peerapol Jirapong
author_sort Wichet Thippresert
title AC flashover performance of porcelain insulators in distribution systems
title_short AC flashover performance of porcelain insulators in distribution systems
title_full AC flashover performance of porcelain insulators in distribution systems
title_fullStr AC flashover performance of porcelain insulators in distribution systems
title_full_unstemmed AC flashover performance of porcelain insulators in distribution systems
title_sort ac flashover performance of porcelain insulators in distribution systems
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84861950005&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51580
_version_ 1681423795427999744