AC flashover performance for line post and pin post insulators in distribution 22 kV

Electrical insulators in 22kV distribution system of the Provincial Electricity Authority (PEA) are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust...

Full description

Saved in:
Bibliographic Details
Main Authors: W. Thipprasert, P. Sritakeaw, P. Jirapong
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84874433713&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51585
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-51585
record_format dspace
spelling th-cmuir.6653943832-515852018-09-04T06:04:45Z AC flashover performance for line post and pin post insulators in distribution 22 kV W. Thipprasert P. Sritakeaw P. Jirapong Engineering Electrical insulators in 22kV distribution system of the Provincial Electricity Authority (PEA) are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE. 2018-09-04T06:04:45Z 2018-09-04T06:04:45Z 2012-12-01 Conference Proceeding 2-s2.0-84874433713 10.1109/VPPC.2012.6422794 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84874433713&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51585
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Engineering
spellingShingle Engineering
W. Thipprasert
P. Sritakeaw
P. Jirapong
AC flashover performance for line post and pin post insulators in distribution 22 kV
description Electrical insulators in 22kV distribution system of the Provincial Electricity Authority (PEA) are mostly porcelain insulator types that consists of suspension, pin type, line post, and pin post insulators. The distribution lines will be polluted by industrial contaminants, salt fog or natural dust. Experience shows that pollution flashover is one of the main natural calamities harming and affecting the voltage stability and reliability of distribution system. This paper compares the test results obtained from artificial pollution tests according to IEC 60507 with line post type and pin post type insulators of medium system under same test conditions. The salt fog test results indicate that the pollution flashover performance of line post insulator is less than to 50 percent of wet power frequency withstand voltage at equivalent salt deposit density (ESDD) = 0.5 mg/cm2 and the leakage current (LC) of line post insulator increased to 10.2 mA at ESDD = 0.5 mg/cm2 at nominal voltage. In the experiment indicate that AC pollution flashover performance of pin post insulator has better than line post insulator in the serious pollution area. © 2012 IEEE.
format Conference Proceeding
author W. Thipprasert
P. Sritakeaw
P. Jirapong
author_facet W. Thipprasert
P. Sritakeaw
P. Jirapong
author_sort W. Thipprasert
title AC flashover performance for line post and pin post insulators in distribution 22 kV
title_short AC flashover performance for line post and pin post insulators in distribution 22 kV
title_full AC flashover performance for line post and pin post insulators in distribution 22 kV
title_fullStr AC flashover performance for line post and pin post insulators in distribution 22 kV
title_full_unstemmed AC flashover performance for line post and pin post insulators in distribution 22 kV
title_sort ac flashover performance for line post and pin post insulators in distribution 22 kv
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84874433713&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51585
_version_ 1681423796323483648