Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing

In this study, we compared the effects of repeated freezing/thawing of human sperm by our in-house method of rapid freezing with slow programmable freezing. Sperm samples from 11 normozoospermic subjects were processed through density gradients and divided into three aliquots: non-frozen, rapid free...

Full description

Saved in:
Bibliographic Details
Main Authors: Teraporn Vutyavanich, Worashorn Lattiwongsakorn, Waraporn Piromlertamorn, Sudarat Samchimchom
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84869075476&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51836
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-51836
record_format dspace
spelling th-cmuir.6653943832-518362018-09-04T06:10:03Z Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing Teraporn Vutyavanich Worashorn Lattiwongsakorn Waraporn Piromlertamorn Sudarat Samchimchom Medicine In this study, we compared the effects of repeated freezing/thawing of human sperm by our in-house method of rapid freezing with slow programmable freezing. Sperm samples from 11 normozoospermic subjects were processed through density gradients and divided into three aliquots: non-frozen, rapid freezing and slow programmable freezing. Sperm in the rapid freezing group had better motility and viability than those in the slow freezing group (P0.01) after the first, second and third cycles of freezing/thawing, but there was no difference in morphology. In the second experiment, rapid freezing was repeated three times in 20 subjects. The samples from each thawing cycle were evaluated for DNA fragmentation using the alkaline comet assay. DNA fragmentation began to increase considerably after the second cycle of freezing/thawing, but to a level that was not clinically important. In the third experiment, rapid freezing was done repeatedly in 10 subjects, until no motile sperm were observed after thawing. The median number of repeated freezing/thawing that yielded no motile sperm was seven (range: 58, mean: 6.8). In conclusion, we demonstrated that repeated freezing/thawing of processed semen using our rapid freezing method gave better results than standard slow programmable freezing. This method can help maximize the usage of precious cryopreserved sperm samples in assisted reproduction technology. © 2012 AJA, SIMM & SJTU. All rights reserved. 2018-09-04T06:10:03Z 2018-09-04T06:10:03Z 2012-11-01 Journal 17457262 1008682X 2-s2.0-84869075476 10.1038/aja.2012.106 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84869075476&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51836
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Teraporn Vutyavanich
Worashorn Lattiwongsakorn
Waraporn Piromlertamorn
Sudarat Samchimchom
Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
description In this study, we compared the effects of repeated freezing/thawing of human sperm by our in-house method of rapid freezing with slow programmable freezing. Sperm samples from 11 normozoospermic subjects were processed through density gradients and divided into three aliquots: non-frozen, rapid freezing and slow programmable freezing. Sperm in the rapid freezing group had better motility and viability than those in the slow freezing group (P0.01) after the first, second and third cycles of freezing/thawing, but there was no difference in morphology. In the second experiment, rapid freezing was repeated three times in 20 subjects. The samples from each thawing cycle were evaluated for DNA fragmentation using the alkaline comet assay. DNA fragmentation began to increase considerably after the second cycle of freezing/thawing, but to a level that was not clinically important. In the third experiment, rapid freezing was done repeatedly in 10 subjects, until no motile sperm were observed after thawing. The median number of repeated freezing/thawing that yielded no motile sperm was seven (range: 58, mean: 6.8). In conclusion, we demonstrated that repeated freezing/thawing of processed semen using our rapid freezing method gave better results than standard slow programmable freezing. This method can help maximize the usage of precious cryopreserved sperm samples in assisted reproduction technology. © 2012 AJA, SIMM & SJTU. All rights reserved.
format Journal
author Teraporn Vutyavanich
Worashorn Lattiwongsakorn
Waraporn Piromlertamorn
Sudarat Samchimchom
author_facet Teraporn Vutyavanich
Worashorn Lattiwongsakorn
Waraporn Piromlertamorn
Sudarat Samchimchom
author_sort Teraporn Vutyavanich
title Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
title_short Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
title_full Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
title_fullStr Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
title_full_unstemmed Repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
title_sort repeated vitrification/warming of human sperm gives better results than repeated slow programmable freezing
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84869075476&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51836
_version_ 1681423841745698816