A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation

DNA conformation change or damage induced by low-energy ion irradiation has been of great interest owing to research developments in ion beam biotechnology and ion beam application in biomedicine. Mechanisms involved in the induction of DNA damage may account for effect from implanting ion charge. I...

Full description

Saved in:
Bibliographic Details
Main Authors: S. Sarapirom, P. Thongkumkoon, K. Prakrajang, S. Anuntalabhochai, L. D. Yu
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84655176595&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51995
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-51995
record_format dspace
spelling th-cmuir.6653943832-519952018-09-04T06:14:34Z A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation S. Sarapirom P. Thongkumkoon K. Prakrajang S. Anuntalabhochai L. D. Yu Physics and Astronomy DNA conformation change or damage induced by low-energy ion irradiation has been of great interest owing to research developments in ion beam biotechnology and ion beam application in biomedicine. Mechanisms involved in the induction of DNA damage may account for effect from implanting ion charge. In order to check this effect, we used both ion beam and neutralized beam at keV energy to bombard naked DNA. Argon or nitrogen ion beam was generated and extracted from a radiofrequency (RF) ion source and neutralized by microwave-driven plasma in the beam path. Plasmid DNA pGFP samples were irradiated with the ion or neutralized beam in vacuum, followed by gel electrophoresis to observe changes in the DNA conformations. It was revealed that the ion charge played a certain role in inducing DNA conformation change. The subsequent DNA transfer into bacteria Escherichia coli (E. coli) for mutation analysis indicated that the charged ion beam induced DNA change had high potential in mutation induction while neutralized beam did not. The intrinsic reason was attributed to additional DNA deformation and contortion caused by ion charge exchange effect so that the ion beam induced DNA damage could hardly be completely repaired, whereas the neutralized beam induced DNA change could be more easily recoverable owing to absence of the additional DNA deformation and contortion. © 2011 Elsevier B.V. All rights reserved. 2018-09-04T06:14:34Z 2018-09-04T06:14:34Z 2012-02-01 Journal 0168583X 2-s2.0-84655176595 10.1016/j.nimb.2011.01.105 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84655176595&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/51995
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Physics and Astronomy
spellingShingle Physics and Astronomy
S. Sarapirom
P. Thongkumkoon
K. Prakrajang
S. Anuntalabhochai
L. D. Yu
A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation
description DNA conformation change or damage induced by low-energy ion irradiation has been of great interest owing to research developments in ion beam biotechnology and ion beam application in biomedicine. Mechanisms involved in the induction of DNA damage may account for effect from implanting ion charge. In order to check this effect, we used both ion beam and neutralized beam at keV energy to bombard naked DNA. Argon or nitrogen ion beam was generated and extracted from a radiofrequency (RF) ion source and neutralized by microwave-driven plasma in the beam path. Plasmid DNA pGFP samples were irradiated with the ion or neutralized beam in vacuum, followed by gel electrophoresis to observe changes in the DNA conformations. It was revealed that the ion charge played a certain role in inducing DNA conformation change. The subsequent DNA transfer into bacteria Escherichia coli (E. coli) for mutation analysis indicated that the charged ion beam induced DNA change had high potential in mutation induction while neutralized beam did not. The intrinsic reason was attributed to additional DNA deformation and contortion caused by ion charge exchange effect so that the ion beam induced DNA damage could hardly be completely repaired, whereas the neutralized beam induced DNA change could be more easily recoverable owing to absence of the additional DNA deformation and contortion. © 2011 Elsevier B.V. All rights reserved.
format Journal
author S. Sarapirom
P. Thongkumkoon
K. Prakrajang
S. Anuntalabhochai
L. D. Yu
author_facet S. Sarapirom
P. Thongkumkoon
K. Prakrajang
S. Anuntalabhochai
L. D. Yu
author_sort S. Sarapirom
title A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation
title_short A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation
title_full A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation
title_fullStr A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation
title_full_unstemmed A comparative study on low-energy ion beam and neutralized beam modifications of naked DNA and biological effect on mutation
title_sort comparative study on low-energy ion beam and neutralized beam modifications of naked dna and biological effect on mutation
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84655176595&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/51995
_version_ 1681423870434738176