Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand)
This work aims to find out the efficiency of simple equipment in comparison with automatic instruments for NO2 measurement, to analyze the correlations of air pollutants obtained from different techniques and to investigate the transformation of - gaseous NO2 to particulate NO3 on PM10 particles. PM...
Saved in:
Main Authors: | , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84880930209&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/52215 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-52215 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-522152018-09-04T09:36:33Z Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) Chanakarn Khamkaew Somporn Chantara Biochemistry, Genetics and Molecular Biology Chemistry Materials Science Mathematics Physics and Astronomy This work aims to find out the efficiency of simple equipment in comparison with automatic instruments for NO2 measurement, to analyze the correlations of air pollutants obtained from different techniques and to investigate the transformation of - gaseous NO2 to particulate NO3 on PM10 particles. PM10 and NO2 samples (n = 47) were collected from the air quality monitoring (AQM) station containing automatic equipment in the urban area of Chiang Mai, Thailand, using both a mini volume air sampler and tailor made passive samplers. High correlations of the concentrations obtained from the two different techniques were observed for both PM10 (r = 0.98) and NO2 (r = 0.94). The results showed high efficiency of the tailor made passive samplers and a significant possibility of using them for NO2 measurement. PM10 and NO2 concentrations were also well correlated (r = 0.93). A correlation between the particulate phase (PM10 and PM10 -bound NO3-) was very strong (r = 0.98), while a correlation between NO2 and - NO3 (r = 0.90), was also high, which revealed transformation of the gas - to particle -phase on PM10 particles. 2018-09-04T09:22:17Z 2018-09-04T09:22:17Z 2013-08-06 Journal 01252526 2-s2.0-84880930209 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84880930209&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/52215 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Biochemistry, Genetics and Molecular Biology Chemistry Materials Science Mathematics Physics and Astronomy |
spellingShingle |
Biochemistry, Genetics and Molecular Biology Chemistry Materials Science Mathematics Physics and Astronomy Chanakarn Khamkaew Somporn Chantara Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) |
description |
This work aims to find out the efficiency of simple equipment in comparison with automatic instruments for NO2 measurement, to analyze the correlations of air pollutants obtained from different techniques and to investigate the transformation of - gaseous NO2 to particulate NO3 on PM10 particles. PM10 and NO2 samples (n = 47) were collected from the air quality monitoring (AQM) station containing automatic equipment in the urban area of Chiang Mai, Thailand, using both a mini volume air sampler and tailor made passive samplers. High correlations of the concentrations obtained from the two different techniques were observed for both PM10 (r = 0.98) and NO2 (r = 0.94). The results showed high efficiency of the tailor made passive samplers and a significant possibility of using them for NO2 measurement. PM10 and NO2 concentrations were also well correlated (r = 0.93). A correlation between the particulate phase (PM10 and PM10 -bound NO3-) was very strong (r = 0.98), while a correlation between NO2 and - NO3 (r = 0.90), was also high, which revealed transformation of the gas - to particle -phase on PM10 particles. |
format |
Journal |
author |
Chanakarn Khamkaew Somporn Chantara |
author_facet |
Chanakarn Khamkaew Somporn Chantara |
author_sort |
Chanakarn Khamkaew |
title |
Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) |
title_short |
Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) |
title_full |
Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) |
title_fullStr |
Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) |
title_full_unstemmed |
Efficiency of a tailor made NO2 passive sampler and correlations of NO2, PM10 and PM10-bound NO3-in urban air of Chiang Mai (Thailand) |
title_sort |
efficiency of a tailor made no2 passive sampler and correlations of no2, pm10 and pm10-bound no3-in urban air of chiang mai (thailand) |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84880930209&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/52215 |
_version_ |
1681423910429523968 |