Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources
A closed-loop pulsating heat pipe with multiple heat sources (CLPHP w/MHS) was invented to be used as a heat transfer medium between a number of heat sources to a single heat sink. However, an issue on the suitable heat source arrangement that causes the heat pipe to have the highest thermal perform...
Saved in:
Main Authors: | , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84894178366&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/53316 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-53316 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-533162018-09-04T10:00:52Z Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources Niti Kammuang-Lue Phrut Sakulchangsatjatai Pradit Terdtoon Chemical Engineering Engineering Physics and Astronomy A closed-loop pulsating heat pipe with multiple heat sources (CLPHP w/MHS) was invented to be used as a heat transfer medium between a number of heat sources to a single heat sink. However, an issue on the suitable heat source arrangement that causes the heat pipe to have the highest thermal performance was suspicious. The CLPHP w/MHS was made of a copper capillary tube with 32 turns. There were three heat sources with nonidentical input heat flux installed along a longitudinal axis in the evaporator section. Experimental investigations were conducted by permuting the heat sources into six unduplicated arrangements. For the vertical CLPHPs, the highest thermal performance is achieved when heat sources are arranged in consecutive order ascending from the lowest heat flux at the inlet of the evaporator section, since working fluid is promoted to circulate in complete one direction and then the heat can transfer more continuously. Finally, for the horizontal CLPHPs, the highest thermal performance is achieved when the heat sources are arranged in opposite order to the case of vertical CLPHPs, that is, descending from the highest heat flux, since working fluid pulsates with no intermission stop and this causes the heat transfer to be not interrupted. © 2014 Copyright Taylor and Francis Group, LLC. 2018-09-04T09:46:54Z 2018-09-04T09:46:54Z 2014-09-02 Journal 15210537 01457632 2-s2.0-84894178366 10.1080/01457632.2013.870000 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84894178366&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/53316 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Chemical Engineering Engineering Physics and Astronomy |
spellingShingle |
Chemical Engineering Engineering Physics and Astronomy Niti Kammuang-Lue Phrut Sakulchangsatjatai Pradit Terdtoon Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
description |
A closed-loop pulsating heat pipe with multiple heat sources (CLPHP w/MHS) was invented to be used as a heat transfer medium between a number of heat sources to a single heat sink. However, an issue on the suitable heat source arrangement that causes the heat pipe to have the highest thermal performance was suspicious. The CLPHP w/MHS was made of a copper capillary tube with 32 turns. There were three heat sources with nonidentical input heat flux installed along a longitudinal axis in the evaporator section. Experimental investigations were conducted by permuting the heat sources into six unduplicated arrangements. For the vertical CLPHPs, the highest thermal performance is achieved when heat sources are arranged in consecutive order ascending from the lowest heat flux at the inlet of the evaporator section, since working fluid is promoted to circulate in complete one direction and then the heat can transfer more continuously. Finally, for the horizontal CLPHPs, the highest thermal performance is achieved when the heat sources are arranged in opposite order to the case of vertical CLPHPs, that is, descending from the highest heat flux, since working fluid pulsates with no intermission stop and this causes the heat transfer to be not interrupted. © 2014 Copyright Taylor and Francis Group, LLC. |
format |
Journal |
author |
Niti Kammuang-Lue Phrut Sakulchangsatjatai Pradit Terdtoon |
author_facet |
Niti Kammuang-Lue Phrut Sakulchangsatjatai Pradit Terdtoon |
author_sort |
Niti Kammuang-Lue |
title |
Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
title_short |
Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
title_full |
Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
title_fullStr |
Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
title_full_unstemmed |
Thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
title_sort |
thermal performance of a closed-loop pulsating heat pipe with multiple heat sources |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84894178366&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/53316 |
_version_ |
1681424112505847808 |