Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables

In this paper, switching overvoltages analysis based on the statistical study approach according to IEC 6007 Insulation Co-ordination are analyzed for the energization of the connected 115 kV underground and submarine cables from Khanom power plant to Samui Island substation. Comparative analysis of...

Full description

Saved in:
Bibliographic Details
Main Authors: P. Thararak, P. Jirapong, P. Jan-Ngoen
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903691929&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/53475
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-53475
record_format dspace
spelling th-cmuir.6653943832-534752018-09-04T09:49:51Z Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables P. Thararak P. Jirapong P. Jan-Ngoen Energy In this paper, switching overvoltages analysis based on the statistical study approach according to IEC 6007 Insulation Co-ordination are analyzed for the energization of the connected 115 kV underground and submarine cables from Khanom power plant to Samui Island substation. Comparative analysis of protection schemes including metal oxide surge arresters and controlled switching are analyzed for controlling switching overvoltages during cable energization. The digital computer simulations are made using PSCAD/EMTDC software. Test results show that the overvoltage values at the sending and receiving ends from the cable energization without surge arresters and controlled switching of circuit breaker can reach up to 1.6-2.0 p.u. In addition, the switching overvoltages can be mitigated by the provision of surge arresters at the two line terminations. Additional limitation of these overvoltages, controlled switching involving individual closing of each phase in the circuit breaker at the optimal point-of-wave can be used. © 2014 Asian Institute of Technology. 2018-09-04T09:49:51Z 2018-09-04T09:49:51Z 2014-01-01 Conference Proceeding 2-s2.0-84903691929 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903691929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/53475
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
P. Thararak
P. Jirapong
P. Jan-Ngoen
Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
description In this paper, switching overvoltages analysis based on the statistical study approach according to IEC 6007 Insulation Co-ordination are analyzed for the energization of the connected 115 kV underground and submarine cables from Khanom power plant to Samui Island substation. Comparative analysis of protection schemes including metal oxide surge arresters and controlled switching are analyzed for controlling switching overvoltages during cable energization. The digital computer simulations are made using PSCAD/EMTDC software. Test results show that the overvoltage values at the sending and receiving ends from the cable energization without surge arresters and controlled switching of circuit breaker can reach up to 1.6-2.0 p.u. In addition, the switching overvoltages can be mitigated by the provision of surge arresters at the two line terminations. Additional limitation of these overvoltages, controlled switching involving individual closing of each phase in the circuit breaker at the optimal point-of-wave can be used. © 2014 Asian Institute of Technology.
format Conference Proceeding
author P. Thararak
P. Jirapong
P. Jan-Ngoen
author_facet P. Thararak
P. Jirapong
P. Jan-Ngoen
author_sort P. Thararak
title Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
title_short Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
title_full Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
title_fullStr Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
title_full_unstemmed Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
title_sort analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903691929&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/53475
_version_ 1681424142170062848