Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor
Stable silk fibroin (SF) membranes were prepared by modifying SF with polyethylene glycol diglycidyl ether (PEGDE) for use as enzyme immobilizing matrix. Morphology, structure, and water solubility of the modified silk fibroin (MSF) membrane were investigated. SEM images revealed greater porosity in...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-62949151555&partnerID=40&md5=27d7a0fc0344a2b64ffbcac855f75302 http://cmuir.cmu.ac.th/handle/6653943832/5394 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-5394 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-53942014-08-30T02:56:29Z Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor Moorish P. Watanesk S. Watanesk R. Niamsup H. Cheng Q. Deming R.L. Stable silk fibroin (SF) membranes were prepared by modifying SF with polyethylene glycol diglycidyl ether (PEGDE) for use as enzyme immobilizing matrix. Morphology, structure, and water solubility of the modified silk fibroin (MSF) membrane were investigated. SEM images revealed greater porosity in the MSF membranes. IR spectra confirmed the predominant β-sheet conformation when the PEGDE was greater than 4%. In addition, the MSF membranes were highly insoluble within the pH range 4 10. An amperometric glucose biosensor was initially constructed using glucose oxidase (GOx) immobilized on the MSF membrane, coupled to a Prussian Blue (PB) deposited Au electrode. The response characteristics of the biosensors based on the GOx immobilized onto the 4% and 8% PEGDE modified SF membranes (4P-MSF and 8P-MSF) and the methanol treated SF membrane (MT-SF) were investigated. Amperometric measurements at the applied potential of 0.0 V demonstrated that the glucose biosensor based on the GOx immobilized onto the 4P-MSF membrane exhibited high sensitivity to glucose with a short response time, less than 3 s. Moreover, the stability of the biosensors based on the 4P-MSF membranes was better than those based on the MT-SF membrane after 2 weeks of storage in a phosphate buffer of pH 7.0 at 4 °C. These fundamental electroanalytical features of the sensor are therefore expected to be useful in biosensor application © 2008 Trans Tech Publications, Switzerland. 2014-08-30T02:56:29Z 2014-08-30T02:56:29Z 2008 Conference Paper 9780878493562 10226680 75596 http://www.scopus.com/inward/record.url?eid=2-s2.0-62949151555&partnerID=40&md5=27d7a0fc0344a2b64ffbcac855f75302 http://cmuir.cmu.ac.th/handle/6653943832/5394 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Stable silk fibroin (SF) membranes were prepared by modifying SF with polyethylene glycol diglycidyl ether (PEGDE) for use as enzyme immobilizing matrix. Morphology, structure, and water solubility of the modified silk fibroin (MSF) membrane were investigated. SEM images revealed greater porosity in the MSF membranes. IR spectra confirmed the predominant β-sheet conformation when the PEGDE was greater than 4%. In addition, the MSF membranes were highly insoluble within the pH range 4 10. An amperometric glucose biosensor was initially constructed using glucose oxidase (GOx) immobilized on the MSF membrane, coupled to a Prussian Blue (PB) deposited Au electrode. The response characteristics of the biosensors based on the GOx immobilized onto the 4% and 8% PEGDE modified SF membranes (4P-MSF and 8P-MSF) and the methanol treated SF membrane (MT-SF) were investigated. Amperometric measurements at the applied potential of 0.0 V demonstrated that the glucose biosensor based on the GOx immobilized onto the 4P-MSF membrane exhibited high sensitivity to glucose with a short response time, less than 3 s. Moreover, the stability of the biosensors based on the 4P-MSF membranes was better than those based on the MT-SF membrane after 2 weeks of storage in a phosphate buffer of pH 7.0 at 4 °C. These fundamental electroanalytical features of the sensor are therefore expected to be useful in biosensor application © 2008 Trans Tech Publications, Switzerland. |
format |
Conference or Workshop Item |
author |
Moorish P. Watanesk S. Watanesk R. Niamsup H. Cheng Q. Deming R.L. |
spellingShingle |
Moorish P. Watanesk S. Watanesk R. Niamsup H. Cheng Q. Deming R.L. Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor |
author_facet |
Moorish P. Watanesk S. Watanesk R. Niamsup H. Cheng Q. Deming R.L. |
author_sort |
Moorish P. |
title |
Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor |
title_short |
Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor |
title_full |
Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor |
title_fullStr |
Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor |
title_full_unstemmed |
Application of the PEGDE modified silk fibroin membrane to an amperometric glucose biosensor |
title_sort |
application of the pegde modified silk fibroin membrane to an amperometric glucose biosensor |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-62949151555&partnerID=40&md5=27d7a0fc0344a2b64ffbcac855f75302 http://cmuir.cmu.ac.th/handle/6653943832/5394 |
_version_ |
1681420417231749120 |