An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger

© 2015 Elsevier B.V. In this paper, the effects of inlet air RH and air flow rate on positive and negative corona discharges in a corona-needle charger have been experimentally studied and discussed. Its corona discharge characterizations in terms of current-to-voltage relationships of the corona-ne...

Full description

Saved in:
Bibliographic Details
Main Authors: Artit Yawootti, Panich Intra, Nakorn Tippayawong, Phadungsak Rattanadecho
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939456374&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/54117
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-54117
record_format dspace
spelling th-cmuir.6653943832-541172018-09-04T10:25:41Z An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger Artit Yawootti Panich Intra Nakorn Tippayawong Phadungsak Rattanadecho Biochemistry, Genetics and Molecular Biology Engineering Materials Science Physics and Astronomy © 2015 Elsevier B.V. In this paper, the effects of inlet air RH and air flow rate on positive and negative corona discharges in a corona-needle charger have been experimentally studied and discussed. Its corona discharge characterizations in terms of current-to-voltage relationships of the corona-needle charger on the effects of inlet air RH and air flow rate were evaluated at applied corona voltages between 0 and 3.1 kV, an air flow rates between 5 and 15 L/min, a relative humidity between 20 and 90%, and an operating pressure of about 101.3 kPa. Experimental results were shown that discharge current is strongly affected by the RH level of the inlet air. The positive discharge current was found to be decreased with increasing RH value at RH values below 60% and increased with increasing RH value at RH value above 60% in the same corona voltage. The negative discharge current was found to be stable with increasing RH value at RH values below 40% and increased with increasing RH value at RH value above 40% in the same corona voltage. For the air flow rate effects, the positive discharge current was found to slightly decrease when the air flow rate increased at RH value below 90% and to increase with the air flow rate at RH value of 90%. For the negative corona, the discharge current was also found to monotonically decrease when the air flow rate increased. 2018-09-04T10:07:55Z 2018-09-04T10:07:55Z 2015-10-01 Journal 03043886 2-s2.0-84939456374 10.1016/j.elstat.2015.07.011 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939456374&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/54117
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Biochemistry, Genetics and Molecular Biology
Engineering
Materials Science
Physics and Astronomy
spellingShingle Biochemistry, Genetics and Molecular Biology
Engineering
Materials Science
Physics and Astronomy
Artit Yawootti
Panich Intra
Nakorn Tippayawong
Phadungsak Rattanadecho
An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
description © 2015 Elsevier B.V. In this paper, the effects of inlet air RH and air flow rate on positive and negative corona discharges in a corona-needle charger have been experimentally studied and discussed. Its corona discharge characterizations in terms of current-to-voltage relationships of the corona-needle charger on the effects of inlet air RH and air flow rate were evaluated at applied corona voltages between 0 and 3.1 kV, an air flow rates between 5 and 15 L/min, a relative humidity between 20 and 90%, and an operating pressure of about 101.3 kPa. Experimental results were shown that discharge current is strongly affected by the RH level of the inlet air. The positive discharge current was found to be decreased with increasing RH value at RH values below 60% and increased with increasing RH value at RH value above 60% in the same corona voltage. The negative discharge current was found to be stable with increasing RH value at RH values below 40% and increased with increasing RH value at RH value above 40% in the same corona voltage. For the air flow rate effects, the positive discharge current was found to slightly decrease when the air flow rate increased at RH value below 90% and to increase with the air flow rate at RH value of 90%. For the negative corona, the discharge current was also found to monotonically decrease when the air flow rate increased.
format Journal
author Artit Yawootti
Panich Intra
Nakorn Tippayawong
Phadungsak Rattanadecho
author_facet Artit Yawootti
Panich Intra
Nakorn Tippayawong
Phadungsak Rattanadecho
author_sort Artit Yawootti
title An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
title_short An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
title_full An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
title_fullStr An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
title_full_unstemmed An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
title_sort experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939456374&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/54117
_version_ 1681424261284102144