Evaluation of engineering and economic feasibility of micro-hydropower plant project
© 2015 IEEE. This paper presents an evaluation of engineering and economic feasibility of micro-hydropower plant project. The studied site is located at Thanthong village, Mea-On district, Chiang Mai province. The engineering feasibility studies in this project are using 4 different methods of rate...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84946201702&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/54459 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-54459 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-544592018-09-04T10:14:41Z Evaluation of engineering and economic feasibility of micro-hydropower plant project Monton Wongphat Suttichai Premrudeepreechacharn Energy Engineering © 2015 IEEE. This paper presents an evaluation of engineering and economic feasibility of micro-hydropower plant project. The studied site is located at Thanthong village, Mea-On district, Chiang Mai province. The engineering feasibility studies in this project are using 4 different methods of rate of water flow, which are the average runoff from streamflow gauging station, flow rate from floats method, flow rate from current meter and Manning equation. The experimental and calculation results at 100% flow rate for hydropower generation installed capacities for hydropower plant of each method are 86, 44, 54 and 181 kW, respectively. In addition, this hydropower plant can generate power at 349, 175, 218, and 786 MWh per year, respectively. In term of economy feasibility, Manning equation method has the highest Internal Rate of Return (IRR) at 58.74%, which is comparted with streamflow gauging station method has IRR only at 25.23%. Consideration results of IRR and electric energy, it can be concluded that the accuracy of flow rate is a significant factor for evaluation of hydropower project. The accuracy of data could be collected data for long period of time as using in streamflow gauging station, not just only one year period as using in Manning equation. Therefore, the streamflow gauging station method is an appropriated tool for using in feasibility study of micro-hydropower plant project. 2018-09-04T10:13:56Z 2018-09-04T10:13:56Z 2015-08-05 Conference Proceeding 2-s2.0-84946201702 10.1109/IYCE.2015.7180813 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84946201702&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/54459 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Energy Engineering |
spellingShingle |
Energy Engineering Monton Wongphat Suttichai Premrudeepreechacharn Evaluation of engineering and economic feasibility of micro-hydropower plant project |
description |
© 2015 IEEE. This paper presents an evaluation of engineering and economic feasibility of micro-hydropower plant project. The studied site is located at Thanthong village, Mea-On district, Chiang Mai province. The engineering feasibility studies in this project are using 4 different methods of rate of water flow, which are the average runoff from streamflow gauging station, flow rate from floats method, flow rate from current meter and Manning equation. The experimental and calculation results at 100% flow rate for hydropower generation installed capacities for hydropower plant of each method are 86, 44, 54 and 181 kW, respectively. In addition, this hydropower plant can generate power at 349, 175, 218, and 786 MWh per year, respectively. In term of economy feasibility, Manning equation method has the highest Internal Rate of Return (IRR) at 58.74%, which is comparted with streamflow gauging station method has IRR only at 25.23%. Consideration results of IRR and electric energy, it can be concluded that the accuracy of flow rate is a significant factor for evaluation of hydropower project. The accuracy of data could be collected data for long period of time as using in streamflow gauging station, not just only one year period as using in Manning equation. Therefore, the streamflow gauging station method is an appropriated tool for using in feasibility study of micro-hydropower plant project. |
format |
Conference Proceeding |
author |
Monton Wongphat Suttichai Premrudeepreechacharn |
author_facet |
Monton Wongphat Suttichai Premrudeepreechacharn |
author_sort |
Monton Wongphat |
title |
Evaluation of engineering and economic feasibility of micro-hydropower plant project |
title_short |
Evaluation of engineering and economic feasibility of micro-hydropower plant project |
title_full |
Evaluation of engineering and economic feasibility of micro-hydropower plant project |
title_fullStr |
Evaluation of engineering and economic feasibility of micro-hydropower plant project |
title_full_unstemmed |
Evaluation of engineering and economic feasibility of micro-hydropower plant project |
title_sort |
evaluation of engineering and economic feasibility of micro-hydropower plant project |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84946201702&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/54459 |
_version_ |
1681424324412571648 |