Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil

A novel hydrodynamic sequential injection (HSI) spectrophotometric system for determination of manganese was developed. It is based on the complexation of Mn(II) with formaldoxime in basic solution (pH ≥ 10) to produce product that could be monitored spectrophotometrically at 450nm. Based on the HSI...

Full description

Saved in:
Bibliographic Details
Main Authors: Somnam S., Grudpan K., Jakmunee J.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-49649102898&partnerID=40&md5=6edca4ac4b3de8c2e6e2136056f96f8e
http://cmuir.cmu.ac.th/handle/6653943832/5521
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-5521
record_format dspace
spelling th-cmuir.6653943832-55212014-08-30T02:56:38Z Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil Somnam S. Grudpan K. Jakmunee J. A novel hydrodynamic sequential injection (HSI) spectrophotometric system for determination of manganese was developed. It is based on the complexation of Mn(II) with formaldoxime in basic solution (pH ≥ 10) to produce product that could be monitored spectrophotometrically at 450nm. Based on the HSI concept, both sample and reagents were aspirated through solenoid valves to fill a defined volumes conduit between 3-way connectors connected in series, forming stacked zones of solutions similar to those in normal SI. The concept was successfully demonstrated for manganese determination. A linear calibration graph over a range of 0.5 to 30 mg L-1 Mn(II) with a detection limit of 0.2 mg L-1 was obtained. Relative standard deviations for 11 replicated injections of 5 and 20 mg Mn L-1 were 5.6% and 2.4%, respectively. A sample throughput of 45 h-1 was achieved. The results from investigation of exchangeable manganese in soil samples by the developed method were found to be in good agreement with the results obtained by a batch spectrophotometric method, despite the proposed system employed simpler and more cost-effective devices/instruments, had higher degrees of automation with full microcontroller control of the operation, and consumed smaller amounts of chemicals (250 μL each of hydroxylamine, sample, and formaldoxime solutions and 2.5 mL of buffer carrier solution per operation cycle). Copyright © Taylor & Francis Group, LLC. 2014-08-30T02:56:38Z 2014-08-30T02:56:38Z 2008 Article 00387010 10.1080/00387010802134553 SPLEB http://www.scopus.com/inward/record.url?eid=2-s2.0-49649102898&partnerID=40&md5=6edca4ac4b3de8c2e6e2136056f96f8e http://cmuir.cmu.ac.th/handle/6653943832/5521 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description A novel hydrodynamic sequential injection (HSI) spectrophotometric system for determination of manganese was developed. It is based on the complexation of Mn(II) with formaldoxime in basic solution (pH ≥ 10) to produce product that could be monitored spectrophotometrically at 450nm. Based on the HSI concept, both sample and reagents were aspirated through solenoid valves to fill a defined volumes conduit between 3-way connectors connected in series, forming stacked zones of solutions similar to those in normal SI. The concept was successfully demonstrated for manganese determination. A linear calibration graph over a range of 0.5 to 30 mg L-1 Mn(II) with a detection limit of 0.2 mg L-1 was obtained. Relative standard deviations for 11 replicated injections of 5 and 20 mg Mn L-1 were 5.6% and 2.4%, respectively. A sample throughput of 45 h-1 was achieved. The results from investigation of exchangeable manganese in soil samples by the developed method were found to be in good agreement with the results obtained by a batch spectrophotometric method, despite the proposed system employed simpler and more cost-effective devices/instruments, had higher degrees of automation with full microcontroller control of the operation, and consumed smaller amounts of chemicals (250 μL each of hydroxylamine, sample, and formaldoxime solutions and 2.5 mL of buffer carrier solution per operation cycle). Copyright © Taylor & Francis Group, LLC.
format Article
author Somnam S.
Grudpan K.
Jakmunee J.
spellingShingle Somnam S.
Grudpan K.
Jakmunee J.
Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
author_facet Somnam S.
Grudpan K.
Jakmunee J.
author_sort Somnam S.
title Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
title_short Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
title_full Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
title_fullStr Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
title_full_unstemmed Hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
title_sort hydrodynamic sequential injection spectrophotometric system for determination of manganese in soil
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-49649102898&partnerID=40&md5=6edca4ac4b3de8c2e6e2136056f96f8e
http://cmuir.cmu.ac.th/handle/6653943832/5521
_version_ 1681420441323831296