Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid

A flow injection amperometric method with dialysis sample pretreatment for determination of ascorbic acid (vitamin C) has been developed. Standard/sample solution (50 μL) was injected into a donor stream (deionized water) via an injection valve. The sample zone was passed through a dialysis unit to...

Full description

Saved in:
Bibliographic Details
Main Authors: Bunpeng P., Lapanantnoppakhun S., Jakmunee J.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-67650337111&partnerID=40&md5=dca2f200f191893c8b086599a6eec92e
http://cmuir.cmu.ac.th/handle/6653943832/5542
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-5542
record_format dspace
spelling th-cmuir.6653943832-55422014-08-30T02:56:39Z Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid Bunpeng P. Lapanantnoppakhun S. Jakmunee J. A flow injection amperometric method with dialysis sample pretreatment for determination of ascorbic acid (vitamin C) has been developed. Standard/sample solution (50 μL) was injected into a donor stream (deionized water) via an injection valve. The sample zone was passed through a dialysis unit to separate the analyte from the matrices. The dialysate containing ascorbic acid, in the acceptor stream of 0.1 M phosphate buffer pH 5.6, was flowed to the amperometric detector for current measurement. Ascorbic acid was electrochemically oxidized at glassy carbon electrode giving an anodic peak current proportional to ascorbic acid concentration. A linear calibration graph in range of 50-800 mg/L ascorbic acid was obtained. The relative standard deviation of 10 replicate injections was 1.5 % for 50 mg/L of ascorbic acid. A sample throughput of 20 h-1 was achieved. The proposed method was applied to vitamin C tablets and fruit juice samples collected from drug stores, supermarkets and local suppliers in Chiang Mai. The results obtained for vitamin C samples are agreed well with the labeled values, and comparable with those determined by voltammetric method. The proposed method is rapid, low reagent consumption and does not suffer from colored and colloidal substances presented in the sample. 2014-08-30T02:56:39Z 2014-08-30T02:56:39Z 2008 Article 01252526 http://www.scopus.com/inward/record.url?eid=2-s2.0-67650337111&partnerID=40&md5=dca2f200f191893c8b086599a6eec92e http://cmuir.cmu.ac.th/handle/6653943832/5542 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description A flow injection amperometric method with dialysis sample pretreatment for determination of ascorbic acid (vitamin C) has been developed. Standard/sample solution (50 μL) was injected into a donor stream (deionized water) via an injection valve. The sample zone was passed through a dialysis unit to separate the analyte from the matrices. The dialysate containing ascorbic acid, in the acceptor stream of 0.1 M phosphate buffer pH 5.6, was flowed to the amperometric detector for current measurement. Ascorbic acid was electrochemically oxidized at glassy carbon electrode giving an anodic peak current proportional to ascorbic acid concentration. A linear calibration graph in range of 50-800 mg/L ascorbic acid was obtained. The relative standard deviation of 10 replicate injections was 1.5 % for 50 mg/L of ascorbic acid. A sample throughput of 20 h-1 was achieved. The proposed method was applied to vitamin C tablets and fruit juice samples collected from drug stores, supermarkets and local suppliers in Chiang Mai. The results obtained for vitamin C samples are agreed well with the labeled values, and comparable with those determined by voltammetric method. The proposed method is rapid, low reagent consumption and does not suffer from colored and colloidal substances presented in the sample.
format Article
author Bunpeng P.
Lapanantnoppakhun S.
Jakmunee J.
spellingShingle Bunpeng P.
Lapanantnoppakhun S.
Jakmunee J.
Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid
author_facet Bunpeng P.
Lapanantnoppakhun S.
Jakmunee J.
author_sort Bunpeng P.
title Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid
title_short Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid
title_full Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid
title_fullStr Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid
title_full_unstemmed Flow Injection Amperometric Method with Dialysis Sample Pretreatment for Determination of Ascorbic Acid
title_sort flow injection amperometric method with dialysis sample pretreatment for determination of ascorbic acid
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-67650337111&partnerID=40&md5=dca2f200f191893c8b086599a6eec92e
http://cmuir.cmu.ac.th/handle/6653943832/5542
_version_ 1681420445272768512