Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients

© Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC...

Full description

Saved in:
Bibliographic Details
Main Authors: Sanphat Sangudsup, Tawika Kaewchur, Waralee Teeyasoontranon, Pitchayaponne Klunklin, Nisa Chawapun, Supoj Ua-Apisitwong
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-56131
record_format dspace
spelling th-cmuir.6653943832-561312018-09-05T03:09:24Z Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients Sanphat Sangudsup Tawika Kaewchur Waralee Teeyasoontranon Pitchayaponne Klunklin Nisa Chawapun Supoj Ua-Apisitwong Medicine © Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC patients with PET/CT images were enrolled into this study. Gross tumour volumes (GTVs) were delineated by the PET visual assessment (PETvis), the automated PET (PETauto), standardised uptake value (SUV)>2·5 (PET2·5) and threshold 40% SUVmax (PET40), and CT-based method. For each patient, two IMRT treatment plans based on CT and PET/CT delineation were performed. The target coverage and the dose-volume parameters for organs at risk were analysed. Results: The PETauto referred to PET40 when SUVmax<7 and PET2·5 when SUVmax≥7. The mean GTVs were 15·04, 15·7 and 15·14 cc for PETauto, PETvis and CT based, respectively. The GTV of PETauto was not different from PETvis (p = 0·441) and CT based (p = 0·594). Based on CT delineation in IMRT planning, only 34% of the cases had sufficient PET/CT planning target volumes coverage, whereas the organs at risk dose parameters were not statistically significant (p>0·05). Conclusions: PET/CT enables more accurate assessment of tumour delineation for NSCLC, therefore improve target coverage in IMRT plan. 2018-09-05T03:09:24Z 2018-09-05T03:09:24Z 2016-06-01 Journal 14671131 14603969 2-s2.0-84964319602 10.1017/S1460396916000078 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Sanphat Sangudsup
Tawika Kaewchur
Waralee Teeyasoontranon
Pitchayaponne Klunklin
Nisa Chawapun
Supoj Ua-Apisitwong
Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
description © Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC patients with PET/CT images were enrolled into this study. Gross tumour volumes (GTVs) were delineated by the PET visual assessment (PETvis), the automated PET (PETauto), standardised uptake value (SUV)>2·5 (PET2·5) and threshold 40% SUVmax (PET40), and CT-based method. For each patient, two IMRT treatment plans based on CT and PET/CT delineation were performed. The target coverage and the dose-volume parameters for organs at risk were analysed. Results: The PETauto referred to PET40 when SUVmax<7 and PET2·5 when SUVmax≥7. The mean GTVs were 15·04, 15·7 and 15·14 cc for PETauto, PETvis and CT based, respectively. The GTV of PETauto was not different from PETvis (p = 0·441) and CT based (p = 0·594). Based on CT delineation in IMRT planning, only 34% of the cases had sufficient PET/CT planning target volumes coverage, whereas the organs at risk dose parameters were not statistically significant (p>0·05). Conclusions: PET/CT enables more accurate assessment of tumour delineation for NSCLC, therefore improve target coverage in IMRT plan.
format Journal
author Sanphat Sangudsup
Tawika Kaewchur
Waralee Teeyasoontranon
Pitchayaponne Klunklin
Nisa Chawapun
Supoj Ua-Apisitwong
author_facet Sanphat Sangudsup
Tawika Kaewchur
Waralee Teeyasoontranon
Pitchayaponne Klunklin
Nisa Chawapun
Supoj Ua-Apisitwong
author_sort Sanphat Sangudsup
title Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
title_short Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
title_full Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
title_fullStr Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
title_full_unstemmed Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
title_sort volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (pet/ct) and ct images for target delineation in non-small cell lung cancer patients
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131
_version_ 1681424634729201664