Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients
© Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-56131 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-561312018-09-05T03:09:24Z Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients Sanphat Sangudsup Tawika Kaewchur Waralee Teeyasoontranon Pitchayaponne Klunklin Nisa Chawapun Supoj Ua-Apisitwong Medicine © Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC patients with PET/CT images were enrolled into this study. Gross tumour volumes (GTVs) were delineated by the PET visual assessment (PETvis), the automated PET (PETauto), standardised uptake value (SUV)>2·5 (PET2·5) and threshold 40% SUVmax (PET40), and CT-based method. For each patient, two IMRT treatment plans based on CT and PET/CT delineation were performed. The target coverage and the dose-volume parameters for organs at risk were analysed. Results: The PETauto referred to PET40 when SUVmax<7 and PET2·5 when SUVmax≥7. The mean GTVs were 15·04, 15·7 and 15·14 cc for PETauto, PETvis and CT based, respectively. The GTV of PETauto was not different from PETvis (p = 0·441) and CT based (p = 0·594). Based on CT delineation in IMRT planning, only 34% of the cases had sufficient PET/CT planning target volumes coverage, whereas the organs at risk dose parameters were not statistically significant (p>0·05). Conclusions: PET/CT enables more accurate assessment of tumour delineation for NSCLC, therefore improve target coverage in IMRT plan. 2018-09-05T03:09:24Z 2018-09-05T03:09:24Z 2016-06-01 Journal 14671131 14603969 2-s2.0-84964319602 10.1017/S1460396916000078 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Medicine |
spellingShingle |
Medicine Sanphat Sangudsup Tawika Kaewchur Waralee Teeyasoontranon Pitchayaponne Klunklin Nisa Chawapun Supoj Ua-Apisitwong Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients |
description |
© Cambridge University Press 2016. Purpose: To compare intensity-modulated radiation therapy (IMRT) treatment planning between using positron emission tomography/computed tomography (PET/CT) and CT for target volume delineation in patients with non-small cell lung cancer (NSCLC). Methods: Nine NSCLC patients with PET/CT images were enrolled into this study. Gross tumour volumes (GTVs) were delineated by the PET visual assessment (PETvis), the automated PET (PETauto), standardised uptake value (SUV)>2·5 (PET2·5) and threshold 40% SUVmax (PET40), and CT-based method. For each patient, two IMRT treatment plans based on CT and PET/CT delineation were performed. The target coverage and the dose-volume parameters for organs at risk were analysed. Results: The PETauto referred to PET40 when SUVmax<7 and PET2·5 when SUVmax≥7. The mean GTVs were 15·04, 15·7 and 15·14 cc for PETauto, PETvis and CT based, respectively. The GTV of PETauto was not different from PETvis (p = 0·441) and CT based (p = 0·594). Based on CT delineation in IMRT planning, only 34% of the cases had sufficient PET/CT planning target volumes coverage, whereas the organs at risk dose parameters were not statistically significant (p>0·05). Conclusions: PET/CT enables more accurate assessment of tumour delineation for NSCLC, therefore improve target coverage in IMRT plan. |
format |
Journal |
author |
Sanphat Sangudsup Tawika Kaewchur Waralee Teeyasoontranon Pitchayaponne Klunklin Nisa Chawapun Supoj Ua-Apisitwong |
author_facet |
Sanphat Sangudsup Tawika Kaewchur Waralee Teeyasoontranon Pitchayaponne Klunklin Nisa Chawapun Supoj Ua-Apisitwong |
author_sort |
Sanphat Sangudsup |
title |
Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients |
title_short |
Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients |
title_full |
Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients |
title_fullStr |
Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients |
title_full_unstemmed |
Volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (PET/CT) and CT images for target delineation in non-small cell lung cancer patients |
title_sort |
volumetric and dosimetric comparison of computerised radiotherapy treatment plan between using positron emission tomography/computed tomography (pet/ct) and ct images for target delineation in non-small cell lung cancer patients |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84964319602&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56131 |