A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren
This study developed a portable device to collect exhaled breath condensate (EBC) and used it to collect EBC samples from schoolchildren exposed to ambient PM10. The developed device was validated, including investigating the effect of collecting duration and breathing patterns on EBC volume, with f...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84962591929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56387 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-56387 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-563872018-09-05T03:15:44Z A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren Waraphan Phornwisetsirikun Tippawan Prapamontol Somporn Chantara Prasak Thavornyutikarn Somrak Rangkakulnuwat Multidisciplinary This study developed a portable device to collect exhaled breath condensate (EBC) and used it to collect EBC samples from schoolchildren exposed to ambient PM10. The developed device was validated, including investigating the effect of collecting duration and breathing patterns on EBC volume, with five healthy volunteers. All five volunteers tolerated the device well, completing the EBC collection procedure without difficulty. Collecting normal tidal breathing for 10 minutes yielded the required EBC volume. We conducted a follow-up study with 104 healthy schoolchildren from two different primary schools in Chiang Mai, Thailand. We measured exhaled H2O2concentrations in both the rainy and dry season; ambient PM10was significantly higher in the dry season. In the dry season, the mean exhaled H2O2concentration was significantly higher in both groups (p < 0.05). This study showed that the developed EBC collector device was cost effective, safe, rapid, and simple to use and exhaled H2O2could be used as a biomarker for elevated PM10exposure before clinical symptoms appeared. 2018-09-05T03:15:44Z 2018-09-05T03:15:44Z 2016-01-01 Journal 16851994 2-s2.0-84962591929 10.12982/cmujns.2016.0004 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84962591929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56387 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Multidisciplinary |
spellingShingle |
Multidisciplinary Waraphan Phornwisetsirikun Tippawan Prapamontol Somporn Chantara Prasak Thavornyutikarn Somrak Rangkakulnuwat A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren |
description |
This study developed a portable device to collect exhaled breath condensate (EBC) and used it to collect EBC samples from schoolchildren exposed to ambient PM10. The developed device was validated, including investigating the effect of collecting duration and breathing patterns on EBC volume, with five healthy volunteers. All five volunteers tolerated the device well, completing the EBC collection procedure without difficulty. Collecting normal tidal breathing for 10 minutes yielded the required EBC volume. We conducted a follow-up study with 104 healthy schoolchildren from two different primary schools in Chiang Mai, Thailand. We measured exhaled H2O2concentrations in both the rainy and dry season; ambient PM10was significantly higher in the dry season. In the dry season, the mean exhaled H2O2concentration was significantly higher in both groups (p < 0.05). This study showed that the developed EBC collector device was cost effective, safe, rapid, and simple to use and exhaled H2O2could be used as a biomarker for elevated PM10exposure before clinical symptoms appeared. |
format |
Journal |
author |
Waraphan Phornwisetsirikun Tippawan Prapamontol Somporn Chantara Prasak Thavornyutikarn Somrak Rangkakulnuwat |
author_facet |
Waraphan Phornwisetsirikun Tippawan Prapamontol Somporn Chantara Prasak Thavornyutikarn Somrak Rangkakulnuwat |
author_sort |
Waraphan Phornwisetsirikun |
title |
A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren |
title_short |
A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren |
title_full |
A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren |
title_fullStr |
A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren |
title_full_unstemmed |
A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf>exposure in Thai schoolchildren |
title_sort |
simple device for collecting exhaled breath condensate (ebc) to study inflammatory biomarkers of pm<inf>10</inf>exposure in thai schoolchildren |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84962591929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/56387 |
_version_ |
1681424682401660928 |