Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements

© 2017, The Japan Society for Analytical Chemistry. A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to...

Full description

Saved in:
Bibliographic Details
Main Authors: Sujitra Thaithet, Supaporn Kradtap Hartwell, Somchai Lapanantnoppakhun
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015175225&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57003
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-57003
record_format dspace
spelling th-cmuir.6653943832-570032018-09-05T03:33:40Z Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements Sujitra Thaithet Supaporn Kradtap Hartwell Somchai Lapanantnoppakhun Chemistry © 2017, The Japan Society for Analytical Chemistry. A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (Rs= 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R2being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC. 2018-09-05T03:33:39Z 2018-09-05T03:33:39Z 2017-01-01 Journal 13482246 09106340 2-s2.0-85015175225 10.2116/analsci.33.313 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015175225&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/57003
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
spellingShingle Chemistry
Sujitra Thaithet
Supaporn Kradtap Hartwell
Somchai Lapanantnoppakhun
Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
description © 2017, The Japan Society for Analytical Chemistry. A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (Rs= 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R2being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.
format Journal
author Sujitra Thaithet
Supaporn Kradtap Hartwell
Somchai Lapanantnoppakhun
author_facet Sujitra Thaithet
Supaporn Kradtap Hartwell
Somchai Lapanantnoppakhun
author_sort Sujitra Thaithet
title Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_short Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_full Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_fullStr Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_full_unstemmed Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_sort sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015175225&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57003
_version_ 1681424797740826624