Analysis of power losses for a nine-switch inverter in common-frequency mode application

© 2017 IEEE. Converter power loss analysis is one of the main knowledge bases to further handle and improve the performance and efficiency of the conversion systems. This paper significantly investigates the power losses in the reduced-switch innovation of the nine-switch inverter powering two commo...

Full description

Saved in:
Bibliographic Details
Main Authors: Neerakorn Jarutus, Yuttana Kumsuwan
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85044209702&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57021
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Description
Summary:© 2017 IEEE. Converter power loss analysis is one of the main knowledge bases to further handle and improve the performance and efficiency of the conversion systems. This paper significantly investigates the power losses in the reduced-switch innovation of the nine-switch inverter powering two common three-phase inductive loads with the potential operation of the common-frequency mode. A new contribution is based on a clearer and accurate analysis of the conduction and switching power losses for the insulated-gate bipolar transistors (IGBTs) and the antiparallel diodes in this unique circuit. Using the characteristic-curve-based technique, it is helpful in the simplified, flexible, and straightforward algorithm of mathematical model derivations. Simulation results can verify the proposed power loss analysis.