© 2017 IEEE. This research studies fault diagnosis about an unmanned 8 MW bulb turbine generator of run of river hydro power plant locate far from control and maintenance center by expert system scheme. To assist the inexpert maintenance crews to solve the failure by collecting knowledge from power...

Full description

Saved in:
Bibliographic Details
Main Authors: Isara Buaphan, Suttichai Premrudeepreechacharn
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030158092&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57248
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-57248
record_format dspace
spelling th-cmuir.6653943832-572482018-09-05T03:38:24Z Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant Isara Buaphan Suttichai Premrudeepreechacharn Energy Engineering © 2017 IEEE. This research studies fault diagnosis about an unmanned 8 MW bulb turbine generator of run of river hydro power plant locate far from control and maintenance center by expert system scheme. To assist the inexpert maintenance crews to solve the failure by collecting knowledge from power plant equipment data, maintenance instruction manual, maintenance standard, historical failure events, and body of knowledge from expertise. Translate these information to knowledge base of an expert system by propositional logic. Together with failure analysis of mechanical and electrical equipment that initiate lockout relay signal to shutdown the power plant by fault tree analysis technique for more accuracy and correctness of fault diagnosis. Establishing an inference engine that comprise of failure search rules and problem solving rules. Developing graphical user interface that similar to the SCADA graphic of operator station making inexpert maintenance crews to familiar with the expert system software and easy to use. These will speed up the inexpert maintenance crews to correct the problem as fast as the expertise does. For example, such a case that the generator cannot synchronize to the grid that took the inexpert maintenance crews about 43 hours to correct the problem which lost income about 1,036,080 THB. With the help of the expert system the inexpert maintenance crews could take less than 4 hours to correct this problem and could save loss about 900,000 THB. 2018-09-05T03:37:18Z 2018-09-05T03:37:18Z 2017-08-07 Conference Proceeding 2-s2.0-85030158092 10.1109/IYCE.2017.8003740 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030158092&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/57248
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
Engineering
spellingShingle Energy
Engineering
Isara Buaphan
Suttichai Premrudeepreechacharn
Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant
description © 2017 IEEE. This research studies fault diagnosis about an unmanned 8 MW bulb turbine generator of run of river hydro power plant locate far from control and maintenance center by expert system scheme. To assist the inexpert maintenance crews to solve the failure by collecting knowledge from power plant equipment data, maintenance instruction manual, maintenance standard, historical failure events, and body of knowledge from expertise. Translate these information to knowledge base of an expert system by propositional logic. Together with failure analysis of mechanical and electrical equipment that initiate lockout relay signal to shutdown the power plant by fault tree analysis technique for more accuracy and correctness of fault diagnosis. Establishing an inference engine that comprise of failure search rules and problem solving rules. Developing graphical user interface that similar to the SCADA graphic of operator station making inexpert maintenance crews to familiar with the expert system software and easy to use. These will speed up the inexpert maintenance crews to correct the problem as fast as the expertise does. For example, such a case that the generator cannot synchronize to the grid that took the inexpert maintenance crews about 43 hours to correct the problem which lost income about 1,036,080 THB. With the help of the expert system the inexpert maintenance crews could take less than 4 hours to correct this problem and could save loss about 900,000 THB.
format Conference Proceeding
author Isara Buaphan
Suttichai Premrudeepreechacharn
author_facet Isara Buaphan
Suttichai Premrudeepreechacharn
author_sort Isara Buaphan
title Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant
title_short Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant
title_full Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant
title_fullStr Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant
title_full_unstemmed Development of expert system for fault diagnosis of an 8-MW bulb turbine downstream irrigation hydro power plant
title_sort development of expert system for fault diagnosis of an 8-mw bulb turbine downstream irrigation hydro power plant
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030158092&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57248
_version_ 1681424843540529152