Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images

© 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology Introduction: The application of deformable image registrat...

Full description

Saved in:
Bibliographic Details
Main Authors: Wannapha Nobnop, Hudsaleark Neamin, Imjai Chitapanarux, Somsak Wanwilairat, Vicharn Lorvidhaya, Taweap Sanghangthum
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026485978&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57409
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-57409
record_format dspace
spelling th-cmuir.6653943832-574092018-09-05T03:45:55Z Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images Wannapha Nobnop Hudsaleark Neamin Imjai Chitapanarux Somsak Wanwilairat Vicharn Lorvidhaya Taweap Sanghangthum Health Professions Medicine © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology Introduction: The application of deformable image registration (DIR) to megavoltage computed tomography (MVCT) images benefits adaptive radiotherapy. This study aims to quantify the accuracy of DIR for MVCT images when using different deformation methods assessed in a cubic phantom and nasopharyngeal carcinoma (NPC) patients. Methods: In the control studies, the DIR accuracy in air-tissue and tissue-tissue interface areas was observed using twelve shapes of acrylic and tissue-equivalent material inserted in the phantom. In the clinical studies, the 1st and 20th fraction MVCT images of seven NPC patients were used to evaluate application of DIR. The eight DIR methods used in the DIRART software varied in (i) transformation framework (asymmetric or symmetric), (ii) DIR registration algorithm (Demons or Optical Flow) and (iii) mapping direction (forward or backward). The accuracy of the methods was compared using an intensity-based criterion (correlation coefficient, CC) and volume-based criterion (Dice's similarity coefficient, DSC). Results: The asymmetric transformation with Optical Flow showed the best performance for air-tissue interface areas, with a mean CC and DSC of 0.97 ± 0.03 and 0.79 ± 0.11 respectively. The symmetric transformation with Optical Flow showed good agreement for tissue-tissue interface areas with a CC of (0.99 ± 0.01) and DSC of (0.89 ± 0.03). The sequences of target domains were significantly different in tissue-tissue interface areas. Conclusions: The deformation method and interface area affected the accuracy of DIR. The validation techniques showed satisfactory volume matching of greater than 0.7 with DSC analysis. The methods can yield acceptable results for clinical applications. 2018-09-05T03:40:52Z 2018-09-05T03:40:52Z 2017-12-01 Journal 20513909 20513895 2-s2.0-85026485978 10.1002/jmrs.236 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026485978&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/57409
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Health Professions
Medicine
spellingShingle Health Professions
Medicine
Wannapha Nobnop
Hudsaleark Neamin
Imjai Chitapanarux
Somsak Wanwilairat
Vicharn Lorvidhaya
Taweap Sanghangthum
Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
description © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology Introduction: The application of deformable image registration (DIR) to megavoltage computed tomography (MVCT) images benefits adaptive radiotherapy. This study aims to quantify the accuracy of DIR for MVCT images when using different deformation methods assessed in a cubic phantom and nasopharyngeal carcinoma (NPC) patients. Methods: In the control studies, the DIR accuracy in air-tissue and tissue-tissue interface areas was observed using twelve shapes of acrylic and tissue-equivalent material inserted in the phantom. In the clinical studies, the 1st and 20th fraction MVCT images of seven NPC patients were used to evaluate application of DIR. The eight DIR methods used in the DIRART software varied in (i) transformation framework (asymmetric or symmetric), (ii) DIR registration algorithm (Demons or Optical Flow) and (iii) mapping direction (forward or backward). The accuracy of the methods was compared using an intensity-based criterion (correlation coefficient, CC) and volume-based criterion (Dice's similarity coefficient, DSC). Results: The asymmetric transformation with Optical Flow showed the best performance for air-tissue interface areas, with a mean CC and DSC of 0.97 ± 0.03 and 0.79 ± 0.11 respectively. The symmetric transformation with Optical Flow showed good agreement for tissue-tissue interface areas with a CC of (0.99 ± 0.01) and DSC of (0.89 ± 0.03). The sequences of target domains were significantly different in tissue-tissue interface areas. Conclusions: The deformation method and interface area affected the accuracy of DIR. The validation techniques showed satisfactory volume matching of greater than 0.7 with DSC analysis. The methods can yield acceptable results for clinical applications.
format Journal
author Wannapha Nobnop
Hudsaleark Neamin
Imjai Chitapanarux
Somsak Wanwilairat
Vicharn Lorvidhaya
Taweap Sanghangthum
author_facet Wannapha Nobnop
Hudsaleark Neamin
Imjai Chitapanarux
Somsak Wanwilairat
Vicharn Lorvidhaya
Taweap Sanghangthum
author_sort Wannapha Nobnop
title Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
title_short Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
title_full Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
title_fullStr Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
title_full_unstemmed Accuracy of eight deformable image registration (DIR) methods for tomotherapy megavoltage computed tomography (MVCT) images
title_sort accuracy of eight deformable image registration (dir) methods for tomotherapy megavoltage computed tomography (mvct) images
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85026485978&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57409
_version_ 1681424873547628544