Development of 3D biological effective dose distribution software program

© Cambridge University Press 2016. Purpose To develop a software program to convert physical dose distribution into biological effective dose (BED). Methods The MATLAB-based BED distribution software program was designed to import the radiotherapy treatment plan from the computer treatment planning...

Full description

Saved in:
Bibliographic Details
Main Authors: Patchareewan Khadsiri, Ekkasit Tharavichitkul, Suwit Saekho, Nisa Chawapun
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84986552466&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57561
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-57561
record_format dspace
spelling th-cmuir.6653943832-575612018-09-05T03:45:51Z Development of 3D biological effective dose distribution software program Patchareewan Khadsiri Ekkasit Tharavichitkul Suwit Saekho Nisa Chawapun Medicine © Cambridge University Press 2016. Purpose To develop a software program to convert physical dose distribution into biological effective dose (BED). Methods The MATLAB-based BED distribution software program was designed to import the radiotherapy treatment plan from the computer treatment planning system and to convert the physical dose distribution into the BED distribution. The BED calculation was based on the linear-quadratic-linear model (LQ-L model). Besides radiobiological parameters, other specific data could be fed in through the panel. The accuracy of the program was verified by comparing the BED distribution with manual calculation. Results This software program was able to import the radiotherapy treatment plans and pull out pixel-wised physical dose for BED calculation, and display the isoBED lines on the computed tomographic (CT) image. The verification of BED dose distribution was performed in both phantom and clinical cases. It revealed that there were no differences between the program and manual BED calculations. Conclusion It is feasible and practical to use this in-house BED distribution software program in clinical practices and research work. However, it should be used with caution as the validity of the program depends on the accuracy of the published biological parameters. 2018-09-05T03:45:51Z 2018-09-05T03:45:51Z 2017-12-01 Journal 14671131 14603969 2-s2.0-84986552466 10.1017/S1460396916000339 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84986552466&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/57561
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Patchareewan Khadsiri
Ekkasit Tharavichitkul
Suwit Saekho
Nisa Chawapun
Development of 3D biological effective dose distribution software program
description © Cambridge University Press 2016. Purpose To develop a software program to convert physical dose distribution into biological effective dose (BED). Methods The MATLAB-based BED distribution software program was designed to import the radiotherapy treatment plan from the computer treatment planning system and to convert the physical dose distribution into the BED distribution. The BED calculation was based on the linear-quadratic-linear model (LQ-L model). Besides radiobiological parameters, other specific data could be fed in through the panel. The accuracy of the program was verified by comparing the BED distribution with manual calculation. Results This software program was able to import the radiotherapy treatment plans and pull out pixel-wised physical dose for BED calculation, and display the isoBED lines on the computed tomographic (CT) image. The verification of BED dose distribution was performed in both phantom and clinical cases. It revealed that there were no differences between the program and manual BED calculations. Conclusion It is feasible and practical to use this in-house BED distribution software program in clinical practices and research work. However, it should be used with caution as the validity of the program depends on the accuracy of the published biological parameters.
format Journal
author Patchareewan Khadsiri
Ekkasit Tharavichitkul
Suwit Saekho
Nisa Chawapun
author_facet Patchareewan Khadsiri
Ekkasit Tharavichitkul
Suwit Saekho
Nisa Chawapun
author_sort Patchareewan Khadsiri
title Development of 3D biological effective dose distribution software program
title_short Development of 3D biological effective dose distribution software program
title_full Development of 3D biological effective dose distribution software program
title_fullStr Development of 3D biological effective dose distribution software program
title_full_unstemmed Development of 3D biological effective dose distribution software program
title_sort development of 3d biological effective dose distribution software program
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84986552466&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/57561
_version_ 1681424901658902528