Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes

© 2017 Society of Thermal Engineers of Serbia. The objectives of this study are to experimentally investigate the effect of mean-dering turn numbers on thermal performance and to predict the optimum mean-dering turn number of vertical and horizontal closed-loop pulsating heat pipes. The closed-loop...

Full description

Saved in:
Bibliographic Details
Main Authors: Niti Kammuang-Lue, Phrut Sakulchangsatjatai, Chansin Sriwiset, Pradit Terdtoon
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85044139782&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58657
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-58657
record_format dspace
spelling th-cmuir.6653943832-586572018-09-05T04:27:44Z Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes Niti Kammuang-Lue Phrut Sakulchangsatjatai Chansin Sriwiset Pradit Terdtoon Energy © 2017 Society of Thermal Engineers of Serbia. The objectives of this study are to experimentally investigate the effect of mean-dering turn numbers on thermal performance and to predict the optimum mean-dering turn number of vertical and horizontal closed-loop pulsating heat pipes. The closed-loop pulsating heat pipes were made from a Cu capillary tube with in-ternal diameter of 2.0 mm. The closed-loop pulsating heat pipes were bent into undulating tubes with various meandering turn numbers, such as 5, 7, 10, 16, and 30. Each set of the closed-loop pulsating heat pipes had different evaporator sec-tion lengths of 50 mm and 150 mm. Heat input was supplied to the closed-loop pulsating heat pipe by allowing the flow of distilled water as the heating medium through the evaporator section. The adiabatic section temperature was constant-ly controlled at 50 °C. It could be concluded that the optimum meandering turn number of vertical closed-loop pulsating heat pipes with an evaporator section length of 50 mm is 10 for both R123 and water, and the optimum meandering turn numbers of vertical closed-loop pulsating heat pipes with an evaporator sec-tion length of 150 mm are 5 and 10, respectively, for R123 and water. However, the optimum meandering turn number of the horizontal closed-loop pulsating heat pipes could not be found since the heat flux directly varies with the turn number. In addition, the correlation to predict the optimum meandering turn number of the vertical closed-loop pulsating heat pipes was successfully estab-lished. 2018-09-05T04:27:44Z 2018-09-05T04:27:44Z 2018-01-01 Journal 03549836 2-s2.0-85044139782 10.2298/TSCI150707161K https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85044139782&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/58657
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
Niti Kammuang-Lue
Phrut Sakulchangsatjatai
Chansin Sriwiset
Pradit Terdtoon
Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
description © 2017 Society of Thermal Engineers of Serbia. The objectives of this study are to experimentally investigate the effect of mean-dering turn numbers on thermal performance and to predict the optimum mean-dering turn number of vertical and horizontal closed-loop pulsating heat pipes. The closed-loop pulsating heat pipes were made from a Cu capillary tube with in-ternal diameter of 2.0 mm. The closed-loop pulsating heat pipes were bent into undulating tubes with various meandering turn numbers, such as 5, 7, 10, 16, and 30. Each set of the closed-loop pulsating heat pipes had different evaporator sec-tion lengths of 50 mm and 150 mm. Heat input was supplied to the closed-loop pulsating heat pipe by allowing the flow of distilled water as the heating medium through the evaporator section. The adiabatic section temperature was constant-ly controlled at 50 °C. It could be concluded that the optimum meandering turn number of vertical closed-loop pulsating heat pipes with an evaporator section length of 50 mm is 10 for both R123 and water, and the optimum meandering turn numbers of vertical closed-loop pulsating heat pipes with an evaporator sec-tion length of 150 mm are 5 and 10, respectively, for R123 and water. However, the optimum meandering turn number of the horizontal closed-loop pulsating heat pipes could not be found since the heat flux directly varies with the turn number. In addition, the correlation to predict the optimum meandering turn number of the vertical closed-loop pulsating heat pipes was successfully estab-lished.
format Journal
author Niti Kammuang-Lue
Phrut Sakulchangsatjatai
Chansin Sriwiset
Pradit Terdtoon
author_facet Niti Kammuang-Lue
Phrut Sakulchangsatjatai
Chansin Sriwiset
Pradit Terdtoon
author_sort Niti Kammuang-Lue
title Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_short Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_full Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_fullStr Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_full_unstemmed Investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_sort investigation and prediction of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85044139782&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58657
_version_ 1681425106402803712