Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants

© 2018 by Korean Academy of Rehabilitation Medicine. Objective To determine the effect of very high stimulation frequency (150 and 200 Hz) with wide pulse duration versus 50 Hz with wide pulse duration on stimulated force and fatigue of quadriceps femoris in healthy participants. Methods Thirty-four...

Full description

Saved in:
Bibliographic Details
Main Authors: Kitima Rongsawad, Jonjin Ratanapinunchai
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85046122072&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58942
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-58942
record_format dspace
spelling th-cmuir.6653943832-589422018-09-05T04:35:24Z Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants Kitima Rongsawad Jonjin Ratanapinunchai Medicine © 2018 by Korean Academy of Rehabilitation Medicine. Objective To determine the effect of very high stimulation frequency (150 and 200 Hz) with wide pulse duration versus 50 Hz with wide pulse duration on stimulated force and fatigue of quadriceps femoris in healthy participants. Methods Thirty-four healthy participants underwent fatigue test using three stimulation frequency conditions (50, 150, and 200 Hz) with pulse duration of 0.9 ms. Normalized force values at the end of each fatigue protocol and curve fitting patterns were compared among stimulated frequencies. Results Very high stimulation frequency (150 and 200 Hz) conditions showed a trend of having more decline in normalized stimulated force during fatigue test compared to a low stimulation frequency at 50 Hz. However, the difference was not statistically significant. Responder group showed the same slope of a linear fitting pattern, implying the same pattern of muscle fatigue among three stimulation frequency conditions (-3.32 in 50 Hz, -2.88 in 150 Hz, and -3.14 in 200 Hz, respectively). Conclusion There were high inter-subject variations in the response to different frequency stimulation conditions. However, very high stimulation frequency generated the same fatigue pattern as the low stimulation frequency in the responder group. Further research is needed to explore the mechanism involved. 2018-09-05T04:35:24Z 2018-09-05T04:35:24Z 2018-04-01 Journal 22340653 22340645 2-s2.0-85046122072 10.5535/arm.2018.42.2.250 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85046122072&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/58942
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Kitima Rongsawad
Jonjin Ratanapinunchai
Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
description © 2018 by Korean Academy of Rehabilitation Medicine. Objective To determine the effect of very high stimulation frequency (150 and 200 Hz) with wide pulse duration versus 50 Hz with wide pulse duration on stimulated force and fatigue of quadriceps femoris in healthy participants. Methods Thirty-four healthy participants underwent fatigue test using three stimulation frequency conditions (50, 150, and 200 Hz) with pulse duration of 0.9 ms. Normalized force values at the end of each fatigue protocol and curve fitting patterns were compared among stimulated frequencies. Results Very high stimulation frequency (150 and 200 Hz) conditions showed a trend of having more decline in normalized stimulated force during fatigue test compared to a low stimulation frequency at 50 Hz. However, the difference was not statistically significant. Responder group showed the same slope of a linear fitting pattern, implying the same pattern of muscle fatigue among three stimulation frequency conditions (-3.32 in 50 Hz, -2.88 in 150 Hz, and -3.14 in 200 Hz, respectively). Conclusion There were high inter-subject variations in the response to different frequency stimulation conditions. However, very high stimulation frequency generated the same fatigue pattern as the low stimulation frequency in the responder group. Further research is needed to explore the mechanism involved.
format Journal
author Kitima Rongsawad
Jonjin Ratanapinunchai
author_facet Kitima Rongsawad
Jonjin Ratanapinunchai
author_sort Kitima Rongsawad
title Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
title_short Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
title_full Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
title_fullStr Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
title_full_unstemmed Effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
title_sort effects of very high stimulation frequency and wide-pulse duration on stimulated force and fatigue of quadriceps in healthy participants
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85046122072&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/58942
_version_ 1681425159601258496