Flashover occurrence factor of insulator string with arc horn on high voltage transmission line

This paper describes the occurrence of flashover on insulator surface instead of between the arc horn gap on unbalance insulation double circuit high voltage transmission line, whose lower insulation side has arc horn attach at each insulator strings. Front time and amplitude of lightning strokes an...

Full description

Saved in:
Bibliographic Details
Main Authors: Weerachai Naon, Suttichai Premrudeepreechacharn
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954805995&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59540
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-59540
record_format dspace
spelling th-cmuir.6653943832-595402018-09-10T03:16:56Z Flashover occurrence factor of insulator string with arc horn on high voltage transmission line Weerachai Naon Suttichai Premrudeepreechacharn Energy This paper describes the occurrence of flashover on insulator surface instead of between the arc horn gap on unbalance insulation double circuit high voltage transmission line, whose lower insulation side has arc horn attach at each insulator strings. Front time and amplitude of lightning strokes and interception point of lightning flash were the main factors of this study. The simulations were performed with PSCAD/EMTDC. The main conclusion from the simulation results presented in this paper is only in the case of shielding failure the steepness of wave front and the lightning current magnitude increases, the tendency of insulator surface flashover increases. 2018-09-10T03:16:56Z 2018-09-10T03:16:56Z 2009-12-01 Conference Proceeding 2-s2.0-77954805995 10.1109/NAPS.2009.5484022 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954805995&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/59540
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
Weerachai Naon
Suttichai Premrudeepreechacharn
Flashover occurrence factor of insulator string with arc horn on high voltage transmission line
description This paper describes the occurrence of flashover on insulator surface instead of between the arc horn gap on unbalance insulation double circuit high voltage transmission line, whose lower insulation side has arc horn attach at each insulator strings. Front time and amplitude of lightning strokes and interception point of lightning flash were the main factors of this study. The simulations were performed with PSCAD/EMTDC. The main conclusion from the simulation results presented in this paper is only in the case of shielding failure the steepness of wave front and the lightning current magnitude increases, the tendency of insulator surface flashover increases.
format Conference Proceeding
author Weerachai Naon
Suttichai Premrudeepreechacharn
author_facet Weerachai Naon
Suttichai Premrudeepreechacharn
author_sort Weerachai Naon
title Flashover occurrence factor of insulator string with arc horn on high voltage transmission line
title_short Flashover occurrence factor of insulator string with arc horn on high voltage transmission line
title_full Flashover occurrence factor of insulator string with arc horn on high voltage transmission line
title_fullStr Flashover occurrence factor of insulator string with arc horn on high voltage transmission line
title_full_unstemmed Flashover occurrence factor of insulator string with arc horn on high voltage transmission line
title_sort flashover occurrence factor of insulator string with arc horn on high voltage transmission line
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954805995&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59540
_version_ 1681425270211346432