Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko

Single phase switching has become an increasingly more viable approach to the operation of EHV systems in recent years. Indeed, single phase reclosing, if successful, represents a significant step in improving system performance and is an attractive, economical means of obtaining acceptable transien...

Full description

Saved in:
Bibliographic Details
Main Authors: K. Ngamsanroaj, S. Premrudeepreechacharn
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84869980859&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59543
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-59543
record_format dspace
spelling th-cmuir.6653943832-595432018-09-10T03:16:58Z Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko K. Ngamsanroaj S. Premrudeepreechacharn Energy Single phase switching has become an increasingly more viable approach to the operation of EHV systems in recent years. Indeed, single phase reclosing, if successful, represents a significant step in improving system performance and is an attractive, economical means of obtaining acceptable transient stability with fewer lines. Single phase reclosing has the additional benefits of reducing switching overvoltages. This paper addresses the investigation of single phase reclosing using arc model on the on single and double circuit transmission line employing single phase switching due to single line to ground faults The work is performed by EMTP on the Thailand 500 kV transmission line from Mae Moh to Tha Ta Ko. A series of studies have been performed. © 2009 IEEE. 2018-09-10T03:16:58Z 2018-09-10T03:16:58Z 2009-08-27 Conference Proceeding 21574847 21574839 2-s2.0-84869980859 10.1109/APPEEC.2009.4918448 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84869980859&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/59543
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Energy
spellingShingle Energy
K. Ngamsanroaj
S. Premrudeepreechacharn
Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko
description Single phase switching has become an increasingly more viable approach to the operation of EHV systems in recent years. Indeed, single phase reclosing, if successful, represents a significant step in improving system performance and is an attractive, economical means of obtaining acceptable transient stability with fewer lines. Single phase reclosing has the additional benefits of reducing switching overvoltages. This paper addresses the investigation of single phase reclosing using arc model on the on single and double circuit transmission line employing single phase switching due to single line to ground faults The work is performed by EMTP on the Thailand 500 kV transmission line from Mae Moh to Tha Ta Ko. A series of studies have been performed. © 2009 IEEE.
format Conference Proceeding
author K. Ngamsanroaj
S. Premrudeepreechacharn
author_facet K. Ngamsanroaj
S. Premrudeepreechacharn
author_sort K. Ngamsanroaj
title Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko
title_short Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko
title_full Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko
title_fullStr Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko
title_full_unstemmed Investigation of single phase reclosing using arc model on the 500 kV transmission line from Mae Moh to Tha Ta Ko
title_sort investigation of single phase reclosing using arc model on the 500 kv transmission line from mae moh to tha ta ko
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84869980859&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59543
_version_ 1681425270763945984