Less invasive plate osteosynthesis in humeral shaft fractures

Objective Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of th...

Full description

Saved in:
Bibliographic Details
Main Authors: Theerachai Apivatthakakul, Chanakarn Phornphutkul, Anupong Laohapoonrungsee, Yuddhasert Sirirungruangsarn
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=76049085785&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59759
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-59759
record_format dspace
spelling th-cmuir.6653943832-597592018-09-10T03:21:08Z Less invasive plate osteosynthesis in humeral shaft fractures Theerachai Apivatthakakul Chanakarn Phornphutkul Anupong Laohapoonrungsee Yuddhasert Sirirungruangsarn Medicine Objective Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Indications Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Contraindications Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Surgical Technique Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical conventional screws in each fragment. Results Between January 2003 and January 2006, 23 patients were operated on using the less invasive plate osteosynthesis technique. The minimum follow-up period of 12 months was completed in 20 patients. The mean healing time was 14.6 weeks, defined as three of four cortices having stable bridging callus. In one patient with delayed union, healing was observed after 28 weeks. Functional outcomes were evaluated using the Constant Score and the Hospital for Special Surgery (HSS) Score. 19 patients had good to excellent elbow function with a mean HSS Score of 93.5 points. All patients achieved satisfactory shoulder function with a mean Constant Score of 85.8 points compared to 90.6 on the healthy side. Complications observed were one paresthesia of lateral cutaneous nerve of forearm (no radial nerve injury) and one loosening of the LCP (Locking Compression Plate) screws due to technical error. © Urban & Vogel. 2018-09-10T03:21:08Z 2018-09-10T03:21:08Z 2009-12-01 Journal 14390981 09346694 2-s2.0-76049085785 10.1007/s00064-009-2008-9 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=76049085785&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/59759
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Theerachai Apivatthakakul
Chanakarn Phornphutkul
Anupong Laohapoonrungsee
Yuddhasert Sirirungruangsarn
Less invasive plate osteosynthesis in humeral shaft fractures
description Objective Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Indications Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Contraindications Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Surgical Technique Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical conventional screws in each fragment. Results Between January 2003 and January 2006, 23 patients were operated on using the less invasive plate osteosynthesis technique. The minimum follow-up period of 12 months was completed in 20 patients. The mean healing time was 14.6 weeks, defined as three of four cortices having stable bridging callus. In one patient with delayed union, healing was observed after 28 weeks. Functional outcomes were evaluated using the Constant Score and the Hospital for Special Surgery (HSS) Score. 19 patients had good to excellent elbow function with a mean HSS Score of 93.5 points. All patients achieved satisfactory shoulder function with a mean Constant Score of 85.8 points compared to 90.6 on the healthy side. Complications observed were one paresthesia of lateral cutaneous nerve of forearm (no radial nerve injury) and one loosening of the LCP (Locking Compression Plate) screws due to technical error. © Urban & Vogel.
format Journal
author Theerachai Apivatthakakul
Chanakarn Phornphutkul
Anupong Laohapoonrungsee
Yuddhasert Sirirungruangsarn
author_facet Theerachai Apivatthakakul
Chanakarn Phornphutkul
Anupong Laohapoonrungsee
Yuddhasert Sirirungruangsarn
author_sort Theerachai Apivatthakakul
title Less invasive plate osteosynthesis in humeral shaft fractures
title_short Less invasive plate osteosynthesis in humeral shaft fractures
title_full Less invasive plate osteosynthesis in humeral shaft fractures
title_fullStr Less invasive plate osteosynthesis in humeral shaft fractures
title_full_unstemmed Less invasive plate osteosynthesis in humeral shaft fractures
title_sort less invasive plate osteosynthesis in humeral shaft fractures
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=76049085785&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59759
_version_ 1681425310763974656