Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation

Background: Because of the limited tolerance to portal venous clamping, the model of liver transplantation in rats represents a difficult task, which requires a great proportion of experience. Since techniques that include the introduction of an artificial stent increase the risk of thrombosis, it w...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلفون الرئيسيون: Veeravorn Ariyakhagorn, Volker Schmitz, Peter Olschewski, Dietrich Polenz, Sabine Boas-Knoop, Ulf Neumann, Gero Puhl
التنسيق: دورية
منشور في: 2018
الموضوعات:
الوصول للمادة أونلاين:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=64849084797&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59838
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
id th-cmuir.6653943832-59838
record_format dspace
spelling th-cmuir.6653943832-598382018-09-10T03:22:18Z Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation Veeravorn Ariyakhagorn Volker Schmitz Peter Olschewski Dietrich Polenz Sabine Boas-Knoop Ulf Neumann Gero Puhl Medicine Background: Because of the limited tolerance to portal venous clamping, the model of liver transplantation in rats represents a difficult task, which requires a great proportion of experience. Since techniques that include the introduction of an artificial stent increase the risk of thrombosis, it was our goal to modify the classical vascular hand-sewn venous anastomosis technique by using a modified end-to-end knotless procedure. Materials and methods: Seventy-two animals were randomly assigned to 1 of 2 experimental groups, which differed by the technique for the 3 venous anastomoses (supra- and infrahepatic vena cava, portal vein). Group 1 comprised the established suturing technique for rat liver transplantation, whereas all venous anastomosis of the second group were performed using our modified technique. Results: With our method, average anhepatic time could be significantly reduced from 14 min 10 s (±100 s) to 11 min 40 s (±60 s) (P < 0.001). Kaplan-Meier survival rates demonstrated a better 7-d survival for the knotless (94%) compared to the classic technique (83%) (not significant, P = 0.137). Biliary complications were low in both groups but tended to be higher in the classical group. Conclusions: Our modified knotless anastomosis proves to be equally safe in regard to complications, improves timing, and provides excellent results in the model of orthotopic rat liver transplantation. © 2009 Elsevier Inc. All rights reserved. 2018-09-10T03:22:18Z 2018-09-10T03:22:18Z 2009-05-15 Journal 10958673 00224804 2-s2.0-64849084797 10.1016/j.jss.2008.04.003 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=64849084797&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/59838
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Veeravorn Ariyakhagorn
Volker Schmitz
Peter Olschewski
Dietrich Polenz
Sabine Boas-Knoop
Ulf Neumann
Gero Puhl
Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation
description Background: Because of the limited tolerance to portal venous clamping, the model of liver transplantation in rats represents a difficult task, which requires a great proportion of experience. Since techniques that include the introduction of an artificial stent increase the risk of thrombosis, it was our goal to modify the classical vascular hand-sewn venous anastomosis technique by using a modified end-to-end knotless procedure. Materials and methods: Seventy-two animals were randomly assigned to 1 of 2 experimental groups, which differed by the technique for the 3 venous anastomoses (supra- and infrahepatic vena cava, portal vein). Group 1 comprised the established suturing technique for rat liver transplantation, whereas all venous anastomosis of the second group were performed using our modified technique. Results: With our method, average anhepatic time could be significantly reduced from 14 min 10 s (±100 s) to 11 min 40 s (±60 s) (P < 0.001). Kaplan-Meier survival rates demonstrated a better 7-d survival for the knotless (94%) compared to the classic technique (83%) (not significant, P = 0.137). Biliary complications were low in both groups but tended to be higher in the classical group. Conclusions: Our modified knotless anastomosis proves to be equally safe in regard to complications, improves timing, and provides excellent results in the model of orthotopic rat liver transplantation. © 2009 Elsevier Inc. All rights reserved.
format Journal
author Veeravorn Ariyakhagorn
Volker Schmitz
Peter Olschewski
Dietrich Polenz
Sabine Boas-Knoop
Ulf Neumann
Gero Puhl
author_facet Veeravorn Ariyakhagorn
Volker Schmitz
Peter Olschewski
Dietrich Polenz
Sabine Boas-Knoop
Ulf Neumann
Gero Puhl
author_sort Veeravorn Ariyakhagorn
title Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation
title_short Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation
title_full Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation
title_fullStr Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation
title_full_unstemmed Improvement of Microsurgical Techniques in Orthotopic Rat Liver Transplantation
title_sort improvement of microsurgical techniques in orthotopic rat liver transplantation
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=64849084797&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/59838
_version_ 1681425325425164288