Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture

This research studies the heat transfer characteristic during ice formation of a direct contact heat transfer between carbon dioxide and water mixture. This research is divided into two parts. For the first part, the low temperature carbon dioxide, between - 15 and - 60 °C, is injected into water in...

Full description

Saved in:
Bibliographic Details
Main Authors: S. Thongwik, N. Vorayos, T. Kiatsiriroat, A. Nuntaphan
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=43449126480&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60222
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60222
record_format dspace
spelling th-cmuir.6653943832-602222018-09-10T03:48:24Z Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture S. Thongwik N. Vorayos T. Kiatsiriroat A. Nuntaphan Chemical Engineering Physics and Astronomy This research studies the heat transfer characteristic during ice formation of a direct contact heat transfer between carbon dioxide and water mixture. This research is divided into two parts. For the first part, the low temperature carbon dioxide, between - 15 and - 60 °C, is injected into water initially at 28 °C and exchanges heat directly. The flow rate of carbon dioxide is varied between 0.003 and 0.017 kg/s while the volume of water is between 1 and 3 L. From the experiment, it is found that the effectiveness of the direct contact heat transfer between the carbon dioxide and the water is closed to 100%. Moreover, the lumped model is found to be used for predicting the temperature of water and the mass of ice formation quite well. However, for this technique, the blockage of ice around the injector always occurs. To avoid this problem, slurry ice is considered instead of pure ice. In the second part of this work, the thermal behavior of the slurry ice by direct contact heat transfer technique between carbon dioxide and water mixture is investigated. Compressor oil and Tween 60 are mixed with water for making slurry ice and it is found that the suitable composition is water/oil/Tween 60 at 100/6/1 by volume. Again, the lumped model can be used for predicting the temperature of water mixture and the mass of slurry ice quite well. © 2008 Elsevier Ltd. All rights reserved. 2018-09-10T03:39:33Z 2018-09-10T03:39:33Z 2008-07-01 Journal 07351933 2-s2.0-43449126480 10.1016/j.icheatmasstransfer.2008.02.007 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=43449126480&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60222
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemical Engineering
Physics and Astronomy
spellingShingle Chemical Engineering
Physics and Astronomy
S. Thongwik
N. Vorayos
T. Kiatsiriroat
A. Nuntaphan
Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
description This research studies the heat transfer characteristic during ice formation of a direct contact heat transfer between carbon dioxide and water mixture. This research is divided into two parts. For the first part, the low temperature carbon dioxide, between - 15 and - 60 °C, is injected into water initially at 28 °C and exchanges heat directly. The flow rate of carbon dioxide is varied between 0.003 and 0.017 kg/s while the volume of water is between 1 and 3 L. From the experiment, it is found that the effectiveness of the direct contact heat transfer between the carbon dioxide and the water is closed to 100%. Moreover, the lumped model is found to be used for predicting the temperature of water and the mass of ice formation quite well. However, for this technique, the blockage of ice around the injector always occurs. To avoid this problem, slurry ice is considered instead of pure ice. In the second part of this work, the thermal behavior of the slurry ice by direct contact heat transfer technique between carbon dioxide and water mixture is investigated. Compressor oil and Tween 60 are mixed with water for making slurry ice and it is found that the suitable composition is water/oil/Tween 60 at 100/6/1 by volume. Again, the lumped model can be used for predicting the temperature of water mixture and the mass of slurry ice quite well. © 2008 Elsevier Ltd. All rights reserved.
format Journal
author S. Thongwik
N. Vorayos
T. Kiatsiriroat
A. Nuntaphan
author_facet S. Thongwik
N. Vorayos
T. Kiatsiriroat
A. Nuntaphan
author_sort S. Thongwik
title Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
title_short Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
title_full Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
title_fullStr Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
title_full_unstemmed Thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
title_sort thermal analysis of slurry ice production system using direct contact heat transfer of carbon dioxide and water mixture
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=43449126480&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60222
_version_ 1681425396049903616