Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study

Background and purpose: The methodology developed by IAEA for dosimetric quality control of treatment planning systems has been tested in different hospitals through a pilot study. The aim was to verify the methodology and observe the range of deviations between planned and delivered doses in 3D con...

Full description

Saved in:
Bibliographic Details
Main Authors: Eduard Gershkevitsh, Rainer Schmidt, Graciela Velez, Dan Miller, Erhardt Korf, Fernando Yip, Somsak Wanwilairat, Stanislav Vatnitsky
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=56949088380&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60569
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60569
record_format dspace
spelling th-cmuir.6653943832-605692018-09-10T03:45:33Z Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study Eduard Gershkevitsh Rainer Schmidt Graciela Velez Dan Miller Erhardt Korf Fernando Yip Somsak Wanwilairat Stanislav Vatnitsky Medicine Background and purpose: The methodology developed by IAEA for dosimetric quality control of treatment planning systems has been tested in different hospitals through a pilot study. The aim was to verify the methodology and observe the range of deviations between planned and delivered doses in 3D conformal radiotherapy in situations close to a clinical setting. Material and methods: The methodology was based on an anthropomorphic phantom representing the human thorax, and simulates the whole chain of external beam radiotherapy treatment planning activities. The phantom was scanned using computed tomography and eight test cases were planned on treatment planning systems which imitate different irradiation geometries found in conformal radiotherapy. The doses were measured with ion chambers, and the deviation between measured and treatment planning system calculated doses was reported. This methodology, which employs the same phantom and the same set of test cases, was tested in 17 different hospitals which were using 14 different algorithms/inhomogeneity correction methods implemented in different treatment planning systems. Results: A total of 53 clinical test case datasets for different energies and calculation algorithms were produced. Most of the systems with advanced algorithms complied with predefined agreement criteria. Dose differences more than 20% were discovered for some of the simple algorithms and high energy X-ray beams. The number of deviations outside agreement criteria increases with the beam energy and decreases with advancement of the treatment planning system calculation algorithm. Conclusions: Large deviations exist in some simple dose calculation algorithms, therefore more advanced algorithms would be preferable and therefore should be implemented in clinical practice. The test cases that could be performed in reasonable time would help the users to appreciate the possibilities of their system and understand its limitations. © 2008 Elsevier Ireland Ltd. All rights reserved. 2018-09-10T03:45:33Z 2018-09-10T03:45:33Z 2008-12-01 Journal 01678140 2-s2.0-56949088380 10.1016/j.radonc.2008.07.007 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=56949088380&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60569
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Eduard Gershkevitsh
Rainer Schmidt
Graciela Velez
Dan Miller
Erhardt Korf
Fernando Yip
Somsak Wanwilairat
Stanislav Vatnitsky
Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
description Background and purpose: The methodology developed by IAEA for dosimetric quality control of treatment planning systems has been tested in different hospitals through a pilot study. The aim was to verify the methodology and observe the range of deviations between planned and delivered doses in 3D conformal radiotherapy in situations close to a clinical setting. Material and methods: The methodology was based on an anthropomorphic phantom representing the human thorax, and simulates the whole chain of external beam radiotherapy treatment planning activities. The phantom was scanned using computed tomography and eight test cases were planned on treatment planning systems which imitate different irradiation geometries found in conformal radiotherapy. The doses were measured with ion chambers, and the deviation between measured and treatment planning system calculated doses was reported. This methodology, which employs the same phantom and the same set of test cases, was tested in 17 different hospitals which were using 14 different algorithms/inhomogeneity correction methods implemented in different treatment planning systems. Results: A total of 53 clinical test case datasets for different energies and calculation algorithms were produced. Most of the systems with advanced algorithms complied with predefined agreement criteria. Dose differences more than 20% were discovered for some of the simple algorithms and high energy X-ray beams. The number of deviations outside agreement criteria increases with the beam energy and decreases with advancement of the treatment planning system calculation algorithm. Conclusions: Large deviations exist in some simple dose calculation algorithms, therefore more advanced algorithms would be preferable and therefore should be implemented in clinical practice. The test cases that could be performed in reasonable time would help the users to appreciate the possibilities of their system and understand its limitations. © 2008 Elsevier Ireland Ltd. All rights reserved.
format Journal
author Eduard Gershkevitsh
Rainer Schmidt
Graciela Velez
Dan Miller
Erhardt Korf
Fernando Yip
Somsak Wanwilairat
Stanislav Vatnitsky
author_facet Eduard Gershkevitsh
Rainer Schmidt
Graciela Velez
Dan Miller
Erhardt Korf
Fernando Yip
Somsak Wanwilairat
Stanislav Vatnitsky
author_sort Eduard Gershkevitsh
title Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
title_short Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
title_full Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
title_fullStr Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
title_full_unstemmed Dosimetric verification of radiotherapy treatment planning systems: Results of IAEA pilot study
title_sort dosimetric verification of radiotherapy treatment planning systems: results of iaea pilot study
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=56949088380&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60569
_version_ 1681425460031913984