Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia
Aims: Tissue Doppler imaging has been recently used to evaluate ventricular function in patients with β thalassemia. In clinical practice, serum ferritin is commonly used to assess the severity of iron overload. The aim of this study was to determine which Doppler findings correlated with serum ferr...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=43449133289&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60642 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-60642 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-606422018-09-10T03:46:34Z Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia Suchaya Silvilairat Rekwan Sittiwangkul Yupada Pongprot Pimlak Charoenkwan Charlie Phornphutkul Medicine Aims: Tissue Doppler imaging has been recently used to evaluate ventricular function in patients with β thalassemia. In clinical practice, serum ferritin is commonly used to assess the severity of iron overload. The aim of this study was to determine which Doppler findings correlated with serum ferritin. Methods and results: Thirty-one pediatric patients with transfusion-dependent β thalassemia with normal LVFS were evaluated. Seven patients with serum ferritin <2500 ng/ mL, 13 patients with serum ferritin 2500-5000 ng/mL, and 11 patients with serum ferritin >5000 ng/mL were studied. Diastolic dysfunction was absent in all patients with serum ferritin <2500 ng/mL, and was present in all patients with serum ferritin >5000 ng/mL. Deceleration time (DT) has a significant correlation with serum ferritin (r = -0.59, p < 0.0001). Difference of pulmonary vein atrial reversal flow and mitral valve A wave duration (PVAR - MVA) and early ventricular filling velocity to early diastolic myocardial velocity ratio (E/Em) significantly correlated with serum ferritin (r = 0.49, p = 0.006; r = 0.56, p = 0.001, respectively). Conclusion: Decreased DT, increased PVAR-MVA duration, and increased E/Em ratio reliably reflected severe iron overload in pediatric patients with β thalassemia. Systolic and diastolic LV function is preserved in patients who have serum ferritin <2500 ng/mL. © The Author 2007. 2018-09-10T03:46:34Z 2018-09-10T03:46:34Z 2008-05-01 Journal 15322114 15252167 2-s2.0-43449133289 10.1016/j.euje.2007.06.003 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=43449133289&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60642 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Medicine |
spellingShingle |
Medicine Suchaya Silvilairat Rekwan Sittiwangkul Yupada Pongprot Pimlak Charoenkwan Charlie Phornphutkul Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
description |
Aims: Tissue Doppler imaging has been recently used to evaluate ventricular function in patients with β thalassemia. In clinical practice, serum ferritin is commonly used to assess the severity of iron overload. The aim of this study was to determine which Doppler findings correlated with serum ferritin. Methods and results: Thirty-one pediatric patients with transfusion-dependent β thalassemia with normal LVFS were evaluated. Seven patients with serum ferritin <2500 ng/ mL, 13 patients with serum ferritin 2500-5000 ng/mL, and 11 patients with serum ferritin >5000 ng/mL were studied. Diastolic dysfunction was absent in all patients with serum ferritin <2500 ng/mL, and was present in all patients with serum ferritin >5000 ng/mL. Deceleration time (DT) has a significant correlation with serum ferritin (r = -0.59, p < 0.0001). Difference of pulmonary vein atrial reversal flow and mitral valve A wave duration (PVAR - MVA) and early ventricular filling velocity to early diastolic myocardial velocity ratio (E/Em) significantly correlated with serum ferritin (r = 0.49, p = 0.006; r = 0.56, p = 0.001, respectively). Conclusion: Decreased DT, increased PVAR-MVA duration, and increased E/Em ratio reliably reflected severe iron overload in pediatric patients with β thalassemia. Systolic and diastolic LV function is preserved in patients who have serum ferritin <2500 ng/mL. © The Author 2007. |
format |
Journal |
author |
Suchaya Silvilairat Rekwan Sittiwangkul Yupada Pongprot Pimlak Charoenkwan Charlie Phornphutkul |
author_facet |
Suchaya Silvilairat Rekwan Sittiwangkul Yupada Pongprot Pimlak Charoenkwan Charlie Phornphutkul |
author_sort |
Suchaya Silvilairat |
title |
Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
title_short |
Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
title_full |
Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
title_fullStr |
Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
title_full_unstemmed |
Tissue Doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
title_sort |
tissue doppler echocardiography reliably reflects severity of iron overload in pediatric patients with β thalassemia |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=43449133289&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60642 |
_version_ |
1681425473623556096 |