An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles

Size classification of nanoparticles is an important process in the electrical mobility particle size analyzer. The differential mobility analyzer (DMA) is one of the most commonly used devices for classifying and measuring nanometer-sized aerosol particles between 1 nm to 1 μm in diameter, based on...

Full description

Saved in:
Bibliographic Details
Main Authors: Panich Intra, Nakorn Tippayawong
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=49549110720&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60762
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60762
record_format dspace
spelling th-cmuir.6653943832-607622018-09-10T03:49:31Z An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles Panich Intra Nakorn Tippayawong Multidisciplinary Size classification of nanoparticles is an important process in the electrical mobility particle size analyzer. The differential mobility analyzer (DMA) is one of the most commonly used devices for classifying and measuring nanometer-sized aerosol particles between 1 nm to 1 μm in diameter, based on their electrical mobility. The DMA can be described as an assembly of two concentrically cylindrical electrodes with an air gap between the walls. In the DMA, air and aerosol flows enter from one end, pass through the annulus and exit the other end. An electric field is applied between the inner and outer electrodes. Particles having a specific mobility exit with the monodisperse air flow through a small slit located at the bottom of the inner electrode. These particles are transferred to a particle counter to determine the particle number concentration. In the past several decades, there have been numerous extensive studies and developments on the DMA. Nonetheless, they are different in terms of specific applications, construction, particle size range, as well as time response and resolution. The purpose of this article is to provide an overview of the state-of-the-art existing cylindrical DMAs for aerosol particle size classification as well as for the generation of monodisperse aerosol in nanometer size range. A description of the operating principles, detailed physical characteristics of these DMAs, including the single-channel and multi-channel DMAs, as well as some examples of applications to nanotechnology are given. 2018-09-10T03:49:31Z 2018-09-10T03:49:31Z 2008-03-01 Journal 01253395 2-s2.0-49549110720 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=49549110720&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60762
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Multidisciplinary
spellingShingle Multidisciplinary
Panich Intra
Nakorn Tippayawong
An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
description Size classification of nanoparticles is an important process in the electrical mobility particle size analyzer. The differential mobility analyzer (DMA) is one of the most commonly used devices for classifying and measuring nanometer-sized aerosol particles between 1 nm to 1 μm in diameter, based on their electrical mobility. The DMA can be described as an assembly of two concentrically cylindrical electrodes with an air gap between the walls. In the DMA, air and aerosol flows enter from one end, pass through the annulus and exit the other end. An electric field is applied between the inner and outer electrodes. Particles having a specific mobility exit with the monodisperse air flow through a small slit located at the bottom of the inner electrode. These particles are transferred to a particle counter to determine the particle number concentration. In the past several decades, there have been numerous extensive studies and developments on the DMA. Nonetheless, they are different in terms of specific applications, construction, particle size range, as well as time response and resolution. The purpose of this article is to provide an overview of the state-of-the-art existing cylindrical DMAs for aerosol particle size classification as well as for the generation of monodisperse aerosol in nanometer size range. A description of the operating principles, detailed physical characteristics of these DMAs, including the single-channel and multi-channel DMAs, as well as some examples of applications to nanotechnology are given.
format Journal
author Panich Intra
Nakorn Tippayawong
author_facet Panich Intra
Nakorn Tippayawong
author_sort Panich Intra
title An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
title_short An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
title_full An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
title_fullStr An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
title_full_unstemmed An overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
title_sort overview of differential mobility analyzers for size classification of nanometer-sized aerosol particles
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=49549110720&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60762
_version_ 1681425495735926784