Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay
A flow injection (FI) system with a mini-immunoaffinity chromatographic column was used to perform on-line assays of specific proteoglycans. The 300-μL mini-column contained beads coupled with monoclonal antibodies against the specific sulfation pattern of chondroitin sulfate proteoglycans, which ha...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547424807&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60895 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-60895 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-608952018-09-10T04:01:59Z Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay Supaporn Kradtap Hartwell Kanokphan Pathanon Duriya Fongmoon Prachya Kongtawelert Kate Grudpan Biochemistry, Genetics and Molecular Biology Chemistry A flow injection (FI) system with a mini-immunoaffinity chromatographic column was used to perform on-line assays of specific proteoglycans. The 300-μL mini-column contained beads coupled with monoclonal antibodies against the specific sulfation pattern of chondroitin sulfate proteoglycans, which have been reported to be a potential biomarker for cancer. The amount of these proteoglycans present was estimated indirectly from their protein content using the Bradford assay, which is an alternative to a direct carbohydrate assay. The system developed was tested by assaying for chondroitin sulfate proteoglycans in sera from patients with various cancers and comparing the results to those obtained for sera from healthy people. The results indicated that this approach could be used as a cost-effective alternative system for determining the amount of these specific biomarker proteoglycans. The column could be reused at least 90 times, with each run consisting of 200 μL of serum sample diluted twofold; an analysis rate of 30 min per run was achieved, as compared to 4 h for a batch procedure. © 2007 Springer-Verlag. 2018-09-10T04:00:57Z 2018-09-10T04:00:57Z 2007-08-01 Journal 16182650 16182642 2-s2.0-34547424807 10.1007/s00216-007-1361-5 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547424807&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60895 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Biochemistry, Genetics and Molecular Biology Chemistry |
spellingShingle |
Biochemistry, Genetics and Molecular Biology Chemistry Supaporn Kradtap Hartwell Kanokphan Pathanon Duriya Fongmoon Prachya Kongtawelert Kate Grudpan Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
description |
A flow injection (FI) system with a mini-immunoaffinity chromatographic column was used to perform on-line assays of specific proteoglycans. The 300-μL mini-column contained beads coupled with monoclonal antibodies against the specific sulfation pattern of chondroitin sulfate proteoglycans, which have been reported to be a potential biomarker for cancer. The amount of these proteoglycans present was estimated indirectly from their protein content using the Bradford assay, which is an alternative to a direct carbohydrate assay. The system developed was tested by assaying for chondroitin sulfate proteoglycans in sera from patients with various cancers and comparing the results to those obtained for sera from healthy people. The results indicated that this approach could be used as a cost-effective alternative system for determining the amount of these specific biomarker proteoglycans. The column could be reused at least 90 times, with each run consisting of 200 μL of serum sample diluted twofold; an analysis rate of 30 min per run was achieved, as compared to 4 h for a batch procedure. © 2007 Springer-Verlag. |
format |
Journal |
author |
Supaporn Kradtap Hartwell Kanokphan Pathanon Duriya Fongmoon Prachya Kongtawelert Kate Grudpan |
author_facet |
Supaporn Kradtap Hartwell Kanokphan Pathanon Duriya Fongmoon Prachya Kongtawelert Kate Grudpan |
author_sort |
Supaporn Kradtap Hartwell |
title |
Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
title_short |
Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
title_full |
Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
title_fullStr |
Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
title_full_unstemmed |
Exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
title_sort |
exploiting flow injection system with mini-immunoaffinity chromatographic column for chondroitin sulfate proteoglycans assay |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547424807&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60895 |
_version_ |
1681425520361734144 |