Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit

This research investigates the effect of fly-ash deposit on thermal performance of a cross-flow heat exchanger having a set of spiral finned-tubes as a heat transfer surface. A stream of warm air having high content of fly-ash is exchanging heat with a cool water stream in the tubes. In this study,...

Full description

Saved in:
Bibliographic Details
Main Authors: Atipoang Nuntaphan, Tanongkiat Kiatsiriroat
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34447563670&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60944
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60944
record_format dspace
spelling th-cmuir.6653943832-609442018-09-10T04:03:54Z Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit Atipoang Nuntaphan Tanongkiat Kiatsiriroat Chemical Engineering Engineering This research investigates the effect of fly-ash deposit on thermal performance of a cross-flow heat exchanger having a set of spiral finned-tubes as a heat transfer surface. A stream of warm air having high content of fly-ash is exchanging heat with a cool water stream in the tubes. In this study, the temperature of the heat exchanger surface is lower than the dew point temperature of air, thus there is condensation of moisture in the air stream on the heat exchanger surface. The affecting parameters such as the fin spacing, the air mass flow rate, the fly-ash mass flow rate and the inlet temperature of warm air are varied while the volume flow rate and the inlet temperature of the cold water stream are kept constant at 10 l/min and 5 °C, respectively. From the experiment, it is found that as the testing period is shorter than 8 h the thermal resistance due to the fouling increases with time. Moreover, the deposit of fly-ash on the heat transfer surface is directly proportional to the dust-air ratio and the amount of condensate on heat exchange surface. However, the deposit of fly-ash is inversely proportional to the fin spacing. The empirical model for evaluating the thermal resistance is also developed in this work and the simulated results agree well with those of the measured data. © 2006 Elsevier Inc. All rights reserved. 2018-09-10T04:01:42Z 2018-09-10T04:01:42Z 2007-08-01 Journal 08941777 2-s2.0-34447563670 10.1016/j.expthermflusci.2006.11.007 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34447563670&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60944
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemical Engineering
Engineering
spellingShingle Chemical Engineering
Engineering
Atipoang Nuntaphan
Tanongkiat Kiatsiriroat
Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
description This research investigates the effect of fly-ash deposit on thermal performance of a cross-flow heat exchanger having a set of spiral finned-tubes as a heat transfer surface. A stream of warm air having high content of fly-ash is exchanging heat with a cool water stream in the tubes. In this study, the temperature of the heat exchanger surface is lower than the dew point temperature of air, thus there is condensation of moisture in the air stream on the heat exchanger surface. The affecting parameters such as the fin spacing, the air mass flow rate, the fly-ash mass flow rate and the inlet temperature of warm air are varied while the volume flow rate and the inlet temperature of the cold water stream are kept constant at 10 l/min and 5 °C, respectively. From the experiment, it is found that as the testing period is shorter than 8 h the thermal resistance due to the fouling increases with time. Moreover, the deposit of fly-ash on the heat transfer surface is directly proportional to the dust-air ratio and the amount of condensate on heat exchange surface. However, the deposit of fly-ash is inversely proportional to the fin spacing. The empirical model for evaluating the thermal resistance is also developed in this work and the simulated results agree well with those of the measured data. © 2006 Elsevier Inc. All rights reserved.
format Journal
author Atipoang Nuntaphan
Tanongkiat Kiatsiriroat
author_facet Atipoang Nuntaphan
Tanongkiat Kiatsiriroat
author_sort Atipoang Nuntaphan
title Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
title_short Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
title_full Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
title_fullStr Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
title_full_unstemmed Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
title_sort thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34447563670&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60944
_version_ 1681425529451839488