Effect of inclination angle on free convection thermal performance of louver finned heat exchanger

The effect of inclination angle on the louver finned tube heat exchanger subject to natural convection condition is reported in this study. It is found that the inclination angle plays an importance role on the performance of the louver finned heat exchanger. Performance of the heat exchanger is ass...

Full description

Saved in:
Bibliographic Details
Main Authors: Atipoang Nuntaphan, Sanparwat Vithayasai, Tanongkiat Kiatsiriroat, Chi Chuan Wang
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33750688850&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60948
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60948
record_format dspace
spelling th-cmuir.6653943832-609482018-09-10T04:04:13Z Effect of inclination angle on free convection thermal performance of louver finned heat exchanger Atipoang Nuntaphan Sanparwat Vithayasai Tanongkiat Kiatsiriroat Chi Chuan Wang Chemical Engineering Energy Engineering The effect of inclination angle on the louver finned tube heat exchanger subject to natural convection condition is reported in this study. It is found that the inclination angle plays an importance role on the performance of the louver finned heat exchanger. Performance of the heat exchanger is associated with the interactions between fin, louver, tube, and inclination angle. The heat transfer performance generally decreases with the rise of the inclination angle. This decrease of heat transfer performance is due to the blockage fin and its reversed heat dissipating direction against the raising air. However, at an inclination angle such as 30-45°, a considerable increase of heat transfer performance is seen. This is because appreciable amount of air flow was directed by the louver, causing a "louver-directed" phenomenon as that of in forced convection. With a further increase of inclination angle, the blockage effect caused by the fin is so strong as to offset the "louver-directed" phenomenon. Unlike those shown in force convection, the heat transfer performance decreased with the number of tube row. © 2006 Elsevier Ltd. All rights reserved. 2018-09-10T04:01:46Z 2018-09-10T04:01:46Z 2007-01-01 Journal 00179310 2-s2.0-33750688850 10.1016/j.ijheatmasstransfer.2006.06.008 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33750688850&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60948
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemical Engineering
Energy
Engineering
spellingShingle Chemical Engineering
Energy
Engineering
Atipoang Nuntaphan
Sanparwat Vithayasai
Tanongkiat Kiatsiriroat
Chi Chuan Wang
Effect of inclination angle on free convection thermal performance of louver finned heat exchanger
description The effect of inclination angle on the louver finned tube heat exchanger subject to natural convection condition is reported in this study. It is found that the inclination angle plays an importance role on the performance of the louver finned heat exchanger. Performance of the heat exchanger is associated with the interactions between fin, louver, tube, and inclination angle. The heat transfer performance generally decreases with the rise of the inclination angle. This decrease of heat transfer performance is due to the blockage fin and its reversed heat dissipating direction against the raising air. However, at an inclination angle such as 30-45°, a considerable increase of heat transfer performance is seen. This is because appreciable amount of air flow was directed by the louver, causing a "louver-directed" phenomenon as that of in forced convection. With a further increase of inclination angle, the blockage effect caused by the fin is so strong as to offset the "louver-directed" phenomenon. Unlike those shown in force convection, the heat transfer performance decreased with the number of tube row. © 2006 Elsevier Ltd. All rights reserved.
format Journal
author Atipoang Nuntaphan
Sanparwat Vithayasai
Tanongkiat Kiatsiriroat
Chi Chuan Wang
author_facet Atipoang Nuntaphan
Sanparwat Vithayasai
Tanongkiat Kiatsiriroat
Chi Chuan Wang
author_sort Atipoang Nuntaphan
title Effect of inclination angle on free convection thermal performance of louver finned heat exchanger
title_short Effect of inclination angle on free convection thermal performance of louver finned heat exchanger
title_full Effect of inclination angle on free convection thermal performance of louver finned heat exchanger
title_fullStr Effect of inclination angle on free convection thermal performance of louver finned heat exchanger
title_full_unstemmed Effect of inclination angle on free convection thermal performance of louver finned heat exchanger
title_sort effect of inclination angle on free convection thermal performance of louver finned heat exchanger
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33750688850&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60948
_version_ 1681425530186891264