DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples

A flow injection system with anion exchange resin minicolumns was coupled with dynamic reaction cell (DRC™) ICP-MS for the determination and speciation of selenite and selenate at sub μg L-1levels. The charged selenate and uncharged selenite were separated on the first resin column in which only sel...

Full description

Saved in:
Bibliographic Details
Main Authors: Kritsana Jitmanee, Norio Teshima, Tadao Sakai, Kate Grudpan
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547745904&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60952
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-60952
record_format dspace
spelling th-cmuir.6653943832-609522018-09-10T04:01:54Z DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples Kritsana Jitmanee Norio Teshima Tadao Sakai Kate Grudpan Chemistry A flow injection system with anion exchange resin minicolumns was coupled with dynamic reaction cell (DRC™) ICP-MS for the determination and speciation of selenite and selenate at sub μg L-1levels. The charged selenate and uncharged selenite were separated on the first resin column in which only selenate was retained. The unretained selenite was then deprotonated with alkaline solution, and the resulting anionic selenite species was collected on the second column serially connected downstream. By setting a sample loop, total selenium can be determined together with selenite and selenate. The selenium species was eluted by nitric acid and carried to DRC™ ICP-MS for their detection. Using ammonia as reaction gas, the detection of78Se was improved. The enrichment factor was 20 for 10 mL of sample. The standard deviations (n = 5) of peak heights were 4.9%, 4.1%, and 7.0% for a 5.0 × 10-2μg L-1selenite and selenate, and total Se, respectively. The calibration graphs were linear from 2.0 × 10-2to 1.0 μg L-1selenite and selenate. And, the linearity for total selenium was good in the range of 10.0 × 10-2to 1.0 μg L-1. The proposed method has been demonstrated for the application to natural and bottled drinking water samples. © 2007 Elsevier B.V. All rights reserved. 2018-09-10T04:01:54Z 2018-09-10T04:01:54Z 2007-09-15 Journal 00399140 2-s2.0-34547745904 10.1016/j.talanta.2007.03.054 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547745904&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/60952
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry
spellingShingle Chemistry
Kritsana Jitmanee
Norio Teshima
Tadao Sakai
Kate Grudpan
DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
description A flow injection system with anion exchange resin minicolumns was coupled with dynamic reaction cell (DRC™) ICP-MS for the determination and speciation of selenite and selenate at sub μg L-1levels. The charged selenate and uncharged selenite were separated on the first resin column in which only selenate was retained. The unretained selenite was then deprotonated with alkaline solution, and the resulting anionic selenite species was collected on the second column serially connected downstream. By setting a sample loop, total selenium can be determined together with selenite and selenate. The selenium species was eluted by nitric acid and carried to DRC™ ICP-MS for their detection. Using ammonia as reaction gas, the detection of78Se was improved. The enrichment factor was 20 for 10 mL of sample. The standard deviations (n = 5) of peak heights were 4.9%, 4.1%, and 7.0% for a 5.0 × 10-2μg L-1selenite and selenate, and total Se, respectively. The calibration graphs were linear from 2.0 × 10-2to 1.0 μg L-1selenite and selenate. And, the linearity for total selenium was good in the range of 10.0 × 10-2to 1.0 μg L-1. The proposed method has been demonstrated for the application to natural and bottled drinking water samples. © 2007 Elsevier B.V. All rights reserved.
format Journal
author Kritsana Jitmanee
Norio Teshima
Tadao Sakai
Kate Grudpan
author_facet Kritsana Jitmanee
Norio Teshima
Tadao Sakai
Kate Grudpan
author_sort Kritsana Jitmanee
title DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
title_short DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
title_full DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
title_fullStr DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
title_full_unstemmed DRC™ ICP-MS coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
title_sort drc™ icp-ms coupled with automated flow injection system with anion exchange minicolumns for determination of selenium compounds in water samples
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=34547745904&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/60952
_version_ 1681425530954448896