An optimal PMU placement method against measurement loss and branch outage
This paper presents a new method for an optimal measurement placement of phasor measurement units (PMUs) for power system state estimation. The proposed method considers two types of contingency conditions, i.e. single measurement loss and single branch outage, in order to obtain a reliable measurem...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42549117153&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61038 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-61038 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-610382018-09-10T04:03:09Z An optimal PMU placement method against measurement loss and branch outage Chawasak Rakpenthai Suttichai Premrudeepreechacharn Sermsak Uatrongjit Neville R. Watson Energy This paper presents a new method for an optimal measurement placement of phasor measurement units (PMUs) for power system state estimation. The proposed method considers two types of contingency conditions, i.e. single measurement loss and single branch outage, in order to obtain a reliable measurement system. Firstly, the minimum condition number of the normalized measurement matrix Is used as the criteria in conjunction with the sequential elimination approach to obtain a completely determined condition. Next, a sequential addition approach is used to search for necessary candidates for single measurement loss and single branch outage conditions. These redundant measurements are optimized by the binary integer programming. Finally, in order to minimize the number of PMU placement sites, a heuristic technique to re-arrange measurement positions is also proposed. Numerical results on the IEEE test systems are demonstrated. ©2007 IEEE. 2018-09-10T04:03:09Z 2018-09-10T04:03:09Z 2007-12-01 Conference Proceeding 2-s2.0-42549117153 10.1109/PES.2007.385607 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42549117153&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61038 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Energy |
spellingShingle |
Energy Chawasak Rakpenthai Suttichai Premrudeepreechacharn Sermsak Uatrongjit Neville R. Watson An optimal PMU placement method against measurement loss and branch outage |
description |
This paper presents a new method for an optimal measurement placement of phasor measurement units (PMUs) for power system state estimation. The proposed method considers two types of contingency conditions, i.e. single measurement loss and single branch outage, in order to obtain a reliable measurement system. Firstly, the minimum condition number of the normalized measurement matrix Is used as the criteria in conjunction with the sequential elimination approach to obtain a completely determined condition. Next, a sequential addition approach is used to search for necessary candidates for single measurement loss and single branch outage conditions. These redundant measurements are optimized by the binary integer programming. Finally, in order to minimize the number of PMU placement sites, a heuristic technique to re-arrange measurement positions is also proposed. Numerical results on the IEEE test systems are demonstrated. ©2007 IEEE. |
format |
Conference Proceeding |
author |
Chawasak Rakpenthai Suttichai Premrudeepreechacharn Sermsak Uatrongjit Neville R. Watson |
author_facet |
Chawasak Rakpenthai Suttichai Premrudeepreechacharn Sermsak Uatrongjit Neville R. Watson |
author_sort |
Chawasak Rakpenthai |
title |
An optimal PMU placement method against measurement loss and branch outage |
title_short |
An optimal PMU placement method against measurement loss and branch outage |
title_full |
An optimal PMU placement method against measurement loss and branch outage |
title_fullStr |
An optimal PMU placement method against measurement loss and branch outage |
title_full_unstemmed |
An optimal PMU placement method against measurement loss and branch outage |
title_sort |
optimal pmu placement method against measurement loss and branch outage |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=42549117153&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61038 |
_version_ |
1681425546787946496 |