Cordocentesis in multifetal pregnancies

Objective: To describe the experiences in diagnostic cordocentesis in twin pregnancies at midpregnancy Methods: The database and medical records of pregnant women attending Maternal Fetal Medicine Unit of the hospital for diagnostic cordocentesis at midpregnancy between January 1989 and September 20...

Full description

Saved in:
Bibliographic Details
Main Authors: Fuanglada Tongprasert, Theera Tongsong, Chanane Wanapirak, Supatra Sirichotiyakul, Wirawit Piyamongkol
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=37049024758&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61228
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-61228
record_format dspace
spelling th-cmuir.6653943832-612282018-09-10T04:07:03Z Cordocentesis in multifetal pregnancies Fuanglada Tongprasert Theera Tongsong Chanane Wanapirak Supatra Sirichotiyakul Wirawit Piyamongkol Medicine Objective: To describe the experiences in diagnostic cordocentesis in twin pregnancies at midpregnancy Methods: The database and medical records of pregnant women attending Maternal Fetal Medicine Unit of the hospital for diagnostic cordocentesis at midpregnancy between January 1989 and September 2006 were retrospectively reviewed. Results: During 17 years of experience, 4241 cordocenteses at midpregnancy were performed for prenatal diagnosis, including 59 procedures in 30 multiple pregnancies (29 twins and 1 triplet). The mean gestational age at the time of cordocentesis was 19.5 ± 1.6 weeks. Success rate of the samplings was 98.3% with one sample was maternal blood contamination. Averaged-time used of the procedures was 8.2 minutes (range 1-45 minutes). The procedure-related complications included transient bleeding at puncture site (8.5%) and transient fetal bradycardia (22.0%). The total fetal loss rate was 10.5% but there was no cordocentesis-related fetal loss (0.0%), defined as a fetal loss within 2 weeks after the procedure. Conclusion: This study may provide a new insight on the safety of cordocentesis in multifetal pregnancies at midpregnancy. The procedure-related fetal loss is not as high as reported in the past. This study suggests cordocentesis be a relatively safe and highly successful in obtaining fetal blood samples. Copyright © 2007 John Wiley & Sons, Ltd. 2018-09-10T04:07:03Z 2018-09-10T04:07:03Z 2007-12-01 Journal 10970223 01973851 2-s2.0-37049024758 10.1002/pd.1836 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=37049024758&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61228
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Medicine
spellingShingle Medicine
Fuanglada Tongprasert
Theera Tongsong
Chanane Wanapirak
Supatra Sirichotiyakul
Wirawit Piyamongkol
Cordocentesis in multifetal pregnancies
description Objective: To describe the experiences in diagnostic cordocentesis in twin pregnancies at midpregnancy Methods: The database and medical records of pregnant women attending Maternal Fetal Medicine Unit of the hospital for diagnostic cordocentesis at midpregnancy between January 1989 and September 2006 were retrospectively reviewed. Results: During 17 years of experience, 4241 cordocenteses at midpregnancy were performed for prenatal diagnosis, including 59 procedures in 30 multiple pregnancies (29 twins and 1 triplet). The mean gestational age at the time of cordocentesis was 19.5 ± 1.6 weeks. Success rate of the samplings was 98.3% with one sample was maternal blood contamination. Averaged-time used of the procedures was 8.2 minutes (range 1-45 minutes). The procedure-related complications included transient bleeding at puncture site (8.5%) and transient fetal bradycardia (22.0%). The total fetal loss rate was 10.5% but there was no cordocentesis-related fetal loss (0.0%), defined as a fetal loss within 2 weeks after the procedure. Conclusion: This study may provide a new insight on the safety of cordocentesis in multifetal pregnancies at midpregnancy. The procedure-related fetal loss is not as high as reported in the past. This study suggests cordocentesis be a relatively safe and highly successful in obtaining fetal blood samples. Copyright © 2007 John Wiley & Sons, Ltd.
format Journal
author Fuanglada Tongprasert
Theera Tongsong
Chanane Wanapirak
Supatra Sirichotiyakul
Wirawit Piyamongkol
author_facet Fuanglada Tongprasert
Theera Tongsong
Chanane Wanapirak
Supatra Sirichotiyakul
Wirawit Piyamongkol
author_sort Fuanglada Tongprasert
title Cordocentesis in multifetal pregnancies
title_short Cordocentesis in multifetal pregnancies
title_full Cordocentesis in multifetal pregnancies
title_fullStr Cordocentesis in multifetal pregnancies
title_full_unstemmed Cordocentesis in multifetal pregnancies
title_sort cordocentesis in multifetal pregnancies
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=37049024758&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/61228
_version_ 1681425581611155456