Comparison between measured and predicted ventilation rates in a naturally ventilated greenhouse
A naturally ventilated greenhouse with ridge and side openings in a tropical region has to deal with high temperatures, which adversely affect crop growth. Increasing ventilation rate decreases temperature in the greenhouse. Ventilation rates were predicted using the energy balance method and a mode...