Flow injection chemiluminescence determination of paracetamol
A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by...
Saved in:
Main Authors: | , , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646552993&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61578 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-61578 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-615782018-09-11T08:55:29Z Flow injection chemiluminescence determination of paracetamol Wirat Ruengsitagoon Saisunee Liawruangrath Alan Townshend Chemistry A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample solution was injected into the ruthenium(II) stream (flow rate 1.5 ml min-1) which was then merged with potassium permanganate in dilute sulphuric acid stream (flow rate 0.5 ml min-1). The chemiluminescence intensity is enhanced by the presence of manganese(II) ions. Under the optimum conditions, a linear calibration graph was obtained over the range of 0.3-50.0 μg ml-1and the detection limit was 0.2 μg ml-1(s/n = 3). The relative standard deviation of the proposed method calculated from 20 replicate injections of 5.0 μg ml-1paracetamol was 1.1%. The sample throughput was 90 h-1. The method was successfully applied to the determination of paracetamol in commercial pharmaceutical formulations. © 2005 Elsevier B.V. All rights reserved. 2018-09-11T08:55:29Z 2018-09-11T08:55:29Z 2006-06-15 Journal 00399140 2-s2.0-33646552993 10.1016/j.talanta.2005.11.050 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646552993&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61578 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Chemistry |
spellingShingle |
Chemistry Wirat Ruengsitagoon Saisunee Liawruangrath Alan Townshend Flow injection chemiluminescence determination of paracetamol |
description |
A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample solution was injected into the ruthenium(II) stream (flow rate 1.5 ml min-1) which was then merged with potassium permanganate in dilute sulphuric acid stream (flow rate 0.5 ml min-1). The chemiluminescence intensity is enhanced by the presence of manganese(II) ions. Under the optimum conditions, a linear calibration graph was obtained over the range of 0.3-50.0 μg ml-1and the detection limit was 0.2 μg ml-1(s/n = 3). The relative standard deviation of the proposed method calculated from 20 replicate injections of 5.0 μg ml-1paracetamol was 1.1%. The sample throughput was 90 h-1. The method was successfully applied to the determination of paracetamol in commercial pharmaceutical formulations. © 2005 Elsevier B.V. All rights reserved. |
format |
Journal |
author |
Wirat Ruengsitagoon Saisunee Liawruangrath Alan Townshend |
author_facet |
Wirat Ruengsitagoon Saisunee Liawruangrath Alan Townshend |
author_sort |
Wirat Ruengsitagoon |
title |
Flow injection chemiluminescence determination of paracetamol |
title_short |
Flow injection chemiluminescence determination of paracetamol |
title_full |
Flow injection chemiluminescence determination of paracetamol |
title_fullStr |
Flow injection chemiluminescence determination of paracetamol |
title_full_unstemmed |
Flow injection chemiluminescence determination of paracetamol |
title_sort |
flow injection chemiluminescence determination of paracetamol |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=33646552993&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/61578 |
_version_ |
1681425646840971264 |